Background: Optic nerve head drusen (ONHD) are calcific deposits buried or at the surface of the optic disc. Although ONHD may be associated with progressive visual field defects, the mechanism of drusen-related field loss is poorly understood. Methods for detecting and imaging disc drusen include B-scan ultrasonography, fundus autofluorescence, and optical coherence tomography (OCT). These modalities are useful for drusen detection but are limited by low resolution or poor penetration of deep structures. This review was designed to assess the potential role of new OCT technologies in imaging ONHD.

Evidence Acquisition: Critical appraisal of published literature and comparison of new imaging devices to established technology.

Results: The new imaging modalities of enhanced depth imaging optical coherence tomography (EDI-OCT) and swept source optical coherence tomography (SS-OCT) are able to provide unprecedented in vivo detail of ONHD. Using these devices it is now possible to quantify optic disc drusen dimensions and assess integrity of neighboring retinal structures, including the retinal nerve fiber layer.

Conclusions: EDI-OCT and SS-OCT have the potential to allow better detection of longitudinal changes in drusen and neural retina and improve our understanding of drusen-related visual field loss.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4523639PMC
http://dx.doi.org/10.1097/WNO.0000000000000115DOI Listing

Publication Analysis

Top Keywords

optical coherence
16
coherence tomography
16
optic nerve
8
nerve head
8
head drusen
8
enhanced depth
8
depth imaging
8
swept source
8
source optical
8
optic disc
8

Similar Publications

We uncover emergent universality arising in the equilibration dynamics of multimode continuous-variable systems. Specifically, we study the ensemble of pure states supported on a small subsystem of a few modes, generated by Gaussian measurements on the remaining modes of a globally pure bosonic Gaussian state. We find that beginning from highly entangled, complex global states, such as random Gaussian states and product squeezed states coupled via a deep array of linear optical elements, the induced ensemble attains a universal form, independent of the choice of measurement basis: it is composed of unsqueezed coherent states whose displacements are distributed normally and isotropically, with variance depending on only the particle-number density of the system.

View Article and Find Full Text PDF

Crystalline lens power and astigmatism calculation in myopia by swept-source optical coherence tomography: A pilot study.

Graefes Arch Clin Exp Ophthalmol

January 2025

National Clinical Research Center for Ocular Diseases, Eye Hospital, Wenzhou Medical University, 618# Fengqi East Road, Hangzhou, 310000, Zhejiang, China.

Purpose: To calculate the crystalline lens power and astigmatism, as well as their changes following cycloplegia, in individuals with myopia using swept-source optical coherence tomography (SS-OCT).

Methods: Participants were divided into two groups according to axial length (AL). Crystalline lens parameters, including power, lens thickness (LT), anterior chamber depth (ACD), and astigmatism, were measured with SS-OCT and analysed before and after cycloplegia.

View Article and Find Full Text PDF

Purpose: Reports of gene therapy-associated retinal atrophies and inflammation have highlighted the importance of preclinical safety assessments of adeno-associated virus (AAV) vector systems. We evaluated in nonhuman primates (NHPs) the ocular safety and toxicology of a novel AAV gene therapy targeting retinitis pigmentosa caused by mutations in PDE6A, which has since been used in a phase I/II clinical trial (NCT04611503).

Methods: A total of 34 healthy cynomolgus animals (Macaca fascicularis) were treated with subretinal injections of rAAV.

View Article and Find Full Text PDF

Precis: Current optical coherence tomography normative sample data may not represent diverse human optic nerve anatomy to accurately classify all individuals with true glaucomatous optic neuropathy.

Purpose: To compare optic nerve head (ONH) measurements between published values from an optical coherence tomography (OCT) normative database and a more diverse cohort of healthy individuals.

Patients And Methods: ONH parameters from healthy participants of the Michigan Screening and Intervention for Glaucoma and Eye Health through Telemedicine (MI-SIGHT) program and the Topcon Maestro-1 normative cohort were compared.

View Article and Find Full Text PDF

Vascular Healing After Biodegradable Polymer Sirolimus-Eluting Versus Durable Polymer Everolimus-Eluting Stents in Chronic Total Occlusions.

Catheter Cardiovasc Interv

January 2025

State Key Laboratory of Frigid Zone Cardiovascular Diseases, Cardiovascular Research Institute and Department of Cardiology, General Hospital of Northern Theater Command, Shenyang, China.

Background: Biodegradable polymer stents may reduce the risk of neoatherosclerosis and stent thrombosis. Limited data is available for biodegradable polymer sirolimus-eluting stent (BP-SES) and durable polymer drug-eluting stents (DP-EES) in chronic total occlusions (CTO).

Aim: This study was to evaluate healing patterns of BP-SES versus DP-EES in CTO at 3 and 13 months based on optical coherence tomography (OCT).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!