Electrogastrography (EGG) is a non-invasive diagnostic motility for recording gastric myoelectrical activity. Gastric myoelectrical activity was first recorded in 1922. Advances in recording equipment enabled widespread use of cutaneous EGG after 1985. Later, introduction of multichannel EGG (M-EGG) enabled measurement of electrical activity transmission. At present, M-EGG findings are used as objective indicators of gastric motility disorders caused by various diseases. EGG measures two categories of gastric electrical activity: electrical response activity, or spike potentials; and electrical control activity, or slow waves. The appearance of abnormal rhythmic electrical activity is indicative of abnormalities in gastric motility. The normal frequency range of gastric electrical activity (normogastria) is around 3 cycles per?min. Multiple EGG parameters assist in the assessment of gastric myoelectrical activity, and significant correlations between EGG and other gastric motility tests have been demonstrated in many studies. In Japan, however, EGG remains in the exploratory stage, and its clinical use is limited. There are large variations in procedures and systems used in previous studies, thus there is a need for standardization of EGG procedures and technical terminology. Here, we outline the current status of EGG and report the M-EGG procedures used in our department in addition to our M-EGG findings.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5137273 | PMC |
http://dx.doi.org/10.1540/jsmr.49.78 | DOI Listing |
EJNMMI Phys
January 2025
Department of Medical Radiation Physics and Nuclear Medicine, Karolinska University Hospital, Solna, Sweden.
Background: System calibration is essential for accurate SPECT/CT dosimetry. However, count losses due to dead time and pulse pileup may cause calibration errors, in particular for I, where high count rates may be encountered. Calibration at low count rates should also be avoided to minimise detrimental effects from e.
View Article and Find Full Text PDFSci Rep
January 2025
Department of Electrical Engineering, College of Engineering, King Khalid University, P.O. Box 394, Abha, 61421, KSA, Saudi Arabia.
In wind energy generation systems, ensuring high energy quality is critical but is often compromised due to the limited performance and durability of conventional regulators. To address this, this work presents a novel controller for managing the machine-side inverter of a single-rotor large wind turbine system using an induction machine-type generator. The proposed controller is designed using proportional, integral, and derivative error-based mechanisms, which fundamentally differ from traditional proportional-integral (PI) regulators.
View Article and Find Full Text PDFSci Rep
January 2025
Department of Electrical and Electronics, Faculty of Engineering, Alberoni University, Kapisa, Afghanistan.
This study first proposes an innovative method for optimizing the maximum power extraction from photovoltaic (PV) systems during dynamic and static environmental conditions (DSEC) by applying the horse herd optimization algorithm (HHOA). The HHOA is a bio-inspired technique that mimics the motion cycles of an entire herd of horses. Next, the linear active disturbance rejection control (LADRC) was applied to monitor the HHOA's reference voltage output.
View Article and Find Full Text PDFSci Rep
January 2025
Mallinckrodt Institute of Radiology, Washington University School of Medicine, 4515 McKinley Ave., St. Louis, MO, 63110, USA.
Functional magnetic resonance imaging (fMRI) has dramatically advanced non-invasive human brain mapping and decoding. Functional near-infrared spectroscopy (fNIRS) and high-density diffuse optical tomography (HD-DOT) non-invasively measure blood oxygen fluctuations related to brain activity, like fMRI, at the brain surface, using more-lightweight equipment that circumvents ergonomic and logistical limitations of fMRI. HD-DOT grids have smaller inter-optode spacing (~ 13 mm) than sparse fNIRS (~ 30 mm) and therefore provide higher image quality, with spatial resolution ~ 1/2 that of fMRI, when using the several source-detector distances (13-40 mm) afforded by the HD-DOT grid.
View Article and Find Full Text PDFUltrasound Med Biol
January 2025
School and Graduate Institute of Physical Therapy, College of Medicine, National Taiwan University, Taipei, Taiwan ROC; Center of Physical Therapy, National Taiwan University Hospital, Taipei, Taiwan ROC. Electronic address:
Objective: This study aimed to validate the ultrasound speckle tracking (UST) algorithm, determine the optimal probe location by comparing normalized cross-correlation (NCC) values of muscle displacement at two locations (proximal vs. middle) of the biceps femoris long head (BFlh) using the UST, and investigate the effects of Nordic hamstring curl exercise (NHE) training on BFlh displacement.
Methods: UST efficacy was verified with ex vivo uniaxial testing of porcine leg muscles.