Performance of a rapid multi-analyte 2-photon excitation assay in children with acute respiratory infection.

Diagn Microbiol Infect Dis

Department of Microbiology, Hospital Sant Joan de Deu and University of Barcelona, Passeig Sant Joan de Deu, 08950 Esplugues, Barcelona, Spain. Electronic address:

Published: June 2014

The purpose of this study is to evaluate the diagnostic performance of the novel 2-photon excitation-based mariPOC© Assay (ArcDia Laboratories, Turku, Finland) for antigen detection of respiratory viruses versus real-time polymerase chain reaction (PCR). The mariPOC Assay and 2 multiplex real-time PCR techniques were performed on nasopharyngeal samples from pediatric patients with suspicion of acute respiratory infection admitted to a children's hospital in Spain during October 2011 to January 2013. A total of 233 samples were studied. Sensitivities and specificities (95% confidence interval) of the mariPOC Assay were for respiratory syncytial virus (RSV), 78.4% (69.7-85.6) and 99.2% (96.3-100.0); influenza virus (IFV) A, 66.7% (26.2-94.0) and 99.6% (97.9-100.0); IFV-B, 63.6% (33.6-87.2) and 100.0% (98.7-100.0); human metapneumovirus (hMPV), 60.0% (34.5-81.9) and 100.0% (98.6-100.0); adenovirus (ADV), 12.5% (0.6-48.0) and 100.0% (98.7-100.0), respectively. The mariPOC Assay is a highly specific method for simultaneous detection of 8 respiratory viruses but has sensitivities that range from moderately high for RSV to moderate for IFV and hMPV and low for ADV.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7132766PMC
http://dx.doi.org/10.1016/j.diagmicrobio.2014.02.005DOI Listing

Publication Analysis

Top Keywords

maripoc assay
12
acute respiratory
8
respiratory infection
8
detection respiratory
8
respiratory viruses
8
1000% 987-1000
8
assay
5
respiratory
5
performance rapid
4
rapid multi-analyte
4

Similar Publications

Background: The rapid diagnostics tests for SARS-CoV-2 antigen vary in their sensitivities, and moreover, genomic mutations may further affect the performance of the assays. We aimed to evaluate the analytical performance of an automated antigen assay and compare its sensitivity in Delta- and Omicron-variant positive clinical samples.

Material And Methods: The analytical performance of an automated mariPOC SARS-CoV-2 antigen test was evaluated on a population of community-dwelling subjects with mild respiratory symptoms or being asymptomatic investigated by the RT-qPCR Allplex™ SARS-CoV-2 assay.

View Article and Find Full Text PDF

COVID-19 diagnostics was quickly ramped up worldwide early 2020 based on the detection of viral RNA. However, based on the scientific knowledge for pre-existing coronaviruses, it was expected that the SARS-CoV-2 RNA will be detected from symptomatic and at significant rates also from asymptomatic individuals due to persistence of non-infectious RNA. To increase the efficacy of diagnostics, surveillance, screening and pandemic control, rapid methods, such as antigen tests, are needed for decentralized testing and to assess infectiousness.

View Article and Find Full Text PDF

The objective of this study was to evaluate a novel automated random-access test, mariPOC CDI (ArcDia Ltd., Finland), for the detection of glutamate dehydrogenase (GDH) and toxins A and B directly from fecal specimens. The mariPOC test was compared with both the GenomEra PCR assay (Abacus Diagnostica Oy, Finland) and the TechLab C.

View Article and Find Full Text PDF

Evaluation of a Gastrointestinal Pathogen Panel Immunoassay in Stool Testing of Patients with Suspected () Infection.

J Clin Microbiol

October 2019

Department of Medical Microbiology, 2nd Faculty of Medicine, Charles University, Motol University Hospital, Prague, Czech Republic.

() infection (CDI) is the most common causative pathogen of health care-associated gastrointestinal infections; however, due to the overlap of clinical symptoms with those of other causes of acute gastroenteritis, the selection of the most appropriate laboratory test is difficult. From April to October 2018, 640 stool samples requested for CDI testing were examined using the mariPOC CDI and Gastro test (ArcDia), which allows the detection of glutamate dehydrogenase (GDH) and toxin A/B, norovirus genogroups GI and GII.4, rotavirus, adenovirus, and spp.

View Article and Find Full Text PDF

Microbial identification from faces and urine in one step by two-photon excitation assay technique.

J Immunol Methods

September 2018

ArcDia International Ltd, Lemminkäisenkatu 32, 20520 Turku, Finland.

Two-photon excitation fluorometry (TPX) is a separation-free bioaffinity assay technique which enables accurate diagnostic testing in microvolumes. The technology is currently commercially applied in an automated mariPOC® test system for rapid phenotypic multi-microbe detection of pathogen antigens. The first TPX applications for diagnostics were intended for respiratory infection testing from nasopharyngeal and oropharyngeal samples.

View Article and Find Full Text PDF