A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Efficacy of biologically guided implant site preparation to obtain adequate primary implant stability. | LitMetric

The primary stability of dental implants is essentially influenced by the quality and quantity of hosting bone. To study the effects of adaptation of the drilling protocol to the biological quality of bone estimated by bone density and cortical/cancellous bone ratio, 8.5mm-short implants were placed in different bone types by adapting the drilling protocol to result in a socket under-preparation by 0.2, 0.4, 0.7, 1 and 1.2mm in bone types I, II, III, IV and V, respectively. The effect of the drilling protocol was studied on implant insertion torque and osseointegration. Additionally, we analyzed the relationship of demographic data and social habits to bone type and insertion torque. Then the correlation between insertion torque and bone quality was tested. One hundred ninety two patients (mean age: 62 ± 11 years) participated with 295 implants. The most common bone type at implant site was type III (47.1%) followed by type II (28.1%). Data analysis indicated that gender, age, and social habits had neither correlation with bone type nor with insertion torque. The insertion torque was 59.29 ± 7.27 Ncm for bone type I, 56.51 ± 1.62 Ncm for bone type II, 46.40 ± 1.60 Ncm for bone type III, 34.84 ± 2.38 Ncm for bone type IV and 5 Ncm for bone type V. Statistically significant correlation was found between bone type and insertion torque. The followed drilling protocol adapts socket under-preparation to the needs of establishing a sufficient primary stability for implant osseointegration.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.aanat.2014.02.005DOI Listing

Publication Analysis

Top Keywords

bone type
36
insertion torque
24
ncm bone
20
bone
16
drilling protocol
16
type insertion
12
type
11
implant site
8
primary stability
8
bone types
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!