Objective: The purpose of this article is to present the ABLATE renal ablation planning algorithm (Table 1), which is based on anatomic renal tumor characteristics critical to ablation. [Table: see text].
Conclusion: ABLATE provides a systematic method for reviewing cross-sectional imaging of renal masses for ablation planning purposes. The goal of this system is to help proceduralists anticipate and manage potential technical challenges of renal ablations to maximize oncologic outcomes and minimize complications.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.2214/AJR.13.11110 | DOI Listing |
Lancet Oncol
January 2025
Department of Radiology and Nuclear Medicine, Amsterdam UMC location VUmc, Amsterdam, Netherlands. Electronic address:
Background: For patients with small-size colorectal liver metastases, growing evidence suggests thermal ablation to be associated with fewer adverse events and faster recovery than resection while also challenging resection in terms of local control and overall survival. This study assessed the potential non-inferiority of thermal ablation compared with surgical resection in patients with small-size resectable colorectal liver metastases.
Methods: Adult patients (aged ≥18 years) from 14 centres in the Netherlands, Belgium, and Italy with ten or fewer small-size (≤3 cm) colorectal liver metastases, no extrahepatic metastases, and an Eastern Cooperative Oncology Group performance status of 0-2, were stratified per centre, and according to their disease burden, into low, intermediate, and high disease burden subgroups and randomly assigned 1:1 to receive either thermal ablation (experimental group) or surgical resection (control group) of all target colorectal liver metastases using the web-based module Castor electronic data capture with variable block sizes of 4, 6, and 8.
J Vasc Interv Radiol
January 2025
Gustave Roussy (GR), Département d'Anesthésie Chirurgie et Interventionnelle (DACI), Service d'Imagerie Thérapeutique, Villejuif France; Centre d'Investigation Clinique BIOTHERIS, INSERM CIC1428, Villejuif, France; Radiologie Interventionnelle, Gustave Roussy, Villejuif, France; Laboratoire de Recherche Translationnelle en Immunothérapie (LRTI), INSERM U1015, Villejuif, France; Faculté de Médecine, Paris-Saclay Université, F-94276 Le Kremlin Bicêtre, France.
Purpose: To evaluate the feasibility and accuracy of a robotic device used clinically in soft tissues (abdomen and lung), modified in design and workflow, to perform needle insertion in percutaneous bone procedures.
Methods: The primary objective was safety (severe complications) of robotic-assisted insertion in this new application. Secondary objectives were feasibility (placement technical success), performance (acceptable insertions rate), accuracy (lateral deviation), number of intermediate CT-scans and tolerance (minor/moderate complications).
Herzschrittmacherther Elektrophysiol
January 2025
Sektion Rhythmologie, Klinik für Innere Medizin und Kardiologie, Herzzentrum Dresden, Medizinische Fakultät und Universitätsklinikum Carl Gustav Carus, Technische Universität Dresden, Fetscherstr. 76, 01307, Dresden, Deutschland.
Patients with systolic heart failure (HF) and structural heart disease often suffer from ventricular tachycardias (VTs), which lead to increased morbidity and mortality. Despite advancements in pharmacological therapy and the use of implantable cardioverter-defibrillators, treatment options are limited due to side effects and decreased effectiveness. Catheter ablation (CA) has emerged as a promising therapy for drug-refractory VTs, especially in patients with structural heart disease.
View Article and Find Full Text PDFIntroduction: Early pregnancy care involves the screening and identification of women with risk factors for adverse pregnancy outcomes, including stillbirth or preterm birth, to tailor pregnancy care and interventions accordingly. Most stillbirths and approximately two-thirds of preterm births, however, occur in the absence of evident risk factors. The majority of stillbirths occur in the preterm period, yet there are few interventions targeting this period, and progress to reduce stillbirth rates remains slow.
View Article and Find Full Text PDFInt J Hyperthermia
December 2025
Department of Mechanical Engineering, Brigham Young University, Provo, UT, USA.
Purpose: In magnetic resonance-guided focused ultrasound (MRgFUS) breast therapies, the focal location must be characterized to guide successful treatment. Focal characterization is difficult because heterogeneous breast tissues introduce phase aberrations that blur and shift the focus and traditional guidance methods do not work in adipose tissues. The purpose of this work is to evaluate numerical simulations of MRgFUS that predict the focal location.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!