Purpose: The aim of the paper is to identify, review, analyze, and summarize available evidence in three areas on the use of cross-sectional imaging, specifically maxillofacial cone beam computed tomography (CBCT) in pre- and postoperative dental implant therapy: (1) Available clinical use guidelines, (2) indications and contraindications for use, and (3) assessment of associated radiation dose risk.

Materials And Methods: Three focused questions were developed to address the aims. A systematic literature review was performed using a PICO-based search strategy based on MeSH key words specific to each focused question of English-language publications indexed in the MEDLINE database retrospectively from October 31, 2012. These results were supplemented by a hand search and gray literature search.

Results: Twelve publications were identified providing guidelines for the use of cross-sectional radiography, particularly CBCT imaging, for the pre- and/or postoperative assessment of potential dental implant sites. The publications discovered by the PICO strategy (43 articles), hand (12), and gray literature searches (1) for the second focus question regarding indications and contraindications for CBCT use in implant dentistry were either cohort or case-controlled studies. For the third question on the assessment of associated radiation dose risk, a total of 22 articles were included. Publication characteristics and themes were summarized in tabular format.

Conclusions: The reported indications for CBCT use in implant dentistry vary from preoperative analysis regarding specific anatomic considerations, site development using grafts, and computer-assisted treatment planning to postoperative evaluation focusing on complications due to damage of neurovascular structures. Effective doses for different CBCT devices exhibit a wide range with the lowest dose being almost 100 times less than the highest dose. Significant dose reduction can be achieved by adjusting operating parameters, including exposure factors and reducing the field of view (FOV) to the actual region of interest.

Download full-text PDF

Source
http://dx.doi.org/10.11607/jomi.2014suppl.g1.4DOI Listing

Publication Analysis

Top Keywords

implant dentistry
12
radiation dose
12
cone beam
8
beam computed
8
computed tomography
8
guidelines indications
8
dental implant
8
indications contraindications
8
assessment associated
8
associated radiation
8

Similar Publications

In the present study, porcine-derived collagen type I was covalently immobilized on the surface of titanium (Ti) implants via carboxyl groups introduced by bonded p-vinylbenzoic acid to investigate its in vitro biocompatibility with gingival stem cells and in vivo bone regeneration behavior in the edentulous ridges of Lanyu small-ear pigs at weeks 2 and 6 (short-term effectiveness) through micro-computed tomography and histological analysis. Analytical results found that gingival stem cells showed effective adhesion and spreading on these collagen-immobilized implant surfaces. After 2 and 6 weeks of healing, significant differences in Hounsfield units were observed among the control (week 2 (674.

View Article and Find Full Text PDF

Purpose: Investigating high performance thermoplastic polymers as substitutes to titanium alloy, in fabrication of implants and attachments to support mandibular overdenture, aiming to overcome stress shielding effect of titanium alloy implants. AIM OF STUDY: Assessment of stress distribution in polymeric prosthetic components and bone around polymeric implants, in case of implant-supported mandibular overdenture.

Materials And Methods: 3D finite element model was established for mandibular overdenture, supported bilaterally by two implants at canine region, and retained by two ball attachments.

View Article and Find Full Text PDF

The morbidity of oral disorders, including gingivitis, caries, endodontic-periodontal diseases, and oral cancer, is relatively high globally. Pathogenic cells are the root cause of many oral disorders, and oral therapies depend on eradicating them. Photodynamic therapy (PDT) has been established as a potential and non-invasive local adjuvant treatment for oral disorders.

View Article and Find Full Text PDF

Objective: Peri-implant diseases (peri-implant mucositis and peri-implantitis) are inflammatory conditions that affect the peri-implant tissues and are induced by microbial biofilms (dental plaque) formed around the implant. Removal of biofilm is the fundamental step in managing peri-implant diseases. Interdental cleaning aids such as interdental brush, unitufted brush, or oral irrigation along with regular toothbrushing are recommended for effective plaque control around implants.

View Article and Find Full Text PDF

Introduction: Chronic inflammation leading to implant failure present major challenges in orthopedics, dentistry, and reconstructive surgery. Titanium alloys, while widely used, often provoke inflammatory complications. Zinc-doped calcium phosphate (CaP) coatings offer potential to enhance implant integration by improving corrosion resistance, bioactivity, and immunocompatibility.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!