Low capacity runner (LCR) rats have been developed by divergent artificial selection for treadmill endurance capacity to explore an aerobic biology-disease connection. The beneficial effects of resveratrol supplementation have been demonstrated in endurance running. In this study it was examined whether 12 weeks of treadmill exercise training and/or resveratrol can retrieve the low running performance of the LCR and impact mitochondrial biogenesis and quality control. Resveratrol regressed running performance in trained LCR (p<0.05). Surprisingly, exercise and resveratrol treatments significantly decreased pAMPK/AMPK, SIRT1, SIRT4, forkhead transcription factor 1 (FOXO1) and mitochondrial transcription factor A (TFAM) levels in these animals (p<0.05). Mitochondrial fusion protein, HSP78 and polynucleotide phosphorylase were significantly induced in LCR-trained, LCR-resveratrol treated, LCR-trained and resveratol treated groups compared to LCR-controls. The data indicate that the AMPK-SIRT1-NAMPT-FOXO1 axis could be important to the limited aerobic endurance capacity of low running capacity rats. Resveratrol supplementation was not beneficial in terms of aerobic endurance performance, mitochondrial biogenesis, or quality control.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3960954PMC
http://dx.doi.org/10.2203/dose-response.13-010.RadakDOI Listing

Publication Analysis

Top Keywords

running performance
12
low running
8
resveratrol
4
resveratrol attenuates
4
attenuates exercise-induced
4
exercise-induced adaptive
4
adaptive responses
4
responses rats
4
rats selectively
4
selectively bred
4

Similar Publications

Introduction: Bony and ligamentous ankle injuries are some of the most commonly treated injuries by orthopedic surgeons. Open ligamentous ankle injuries without an associated fracture or dislocation are rare and to our knowledge have only sparsely been described in the literature. We present a case and successful treatment of an open lateral ankle injury with capsular rupture and ligamentous damage without fracture or dislocation in a 22-year-old female.

View Article and Find Full Text PDF

Comparison of precision of a paperless electronic input method versus the conventional paper form in an andrology laboratory: a prospective study.

Basic Clin Androl

January 2025

Department of Obstetrics and Gynaecology, School of Clinical Medicine, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Pokfulam Road, Hong Kong SAR, Hong Kong.

Background: Manual counting for semen analysis is recommended by the World Health Organization. Technicians performing this usually record their results on a paper worksheet and then enter the data into an electronic laboratory information system. One disadvantage of this approach is the chance of post-analytical transcription errors, which can be reduced by checking the computer entries before reporting by another technician.

View Article and Find Full Text PDF

Reliability of running gait variability measures calculated from inertial measurement units.

J Biomech

January 2025

Sport and Physical Activity Research Centre, Sheffield Hallam University, Olympic Legacy Park, 2 Old Hall Rd, Sheffield S9 3TY, United Kingdom. Electronic address:

Changes to the variability within biomechanical signals may reflect a change in the health of the human system. However, for running gait variability measures calculated from wearable device data, it is unknown whether a between-day difference reflects a shift in system dynamics reflective of a change in human health or is a result of poor between-day reliability of the measurement device or the biomechanical signal. This study investigated the reliability of stride time and sacral acceleration variability measures calculated from inertial measurement units (IMUs).

View Article and Find Full Text PDF

Rationale: Wildlife scientists are quantifying steroid hormones in a growing number of tissues and employing novel methods that must undergo validation before application. This study tested the accuracy and precision of liquid chromatography-tandem mass spectrometry (LC-MS/MS) methods for use on blubber samples from short-finned pilot whales (Globicephala macrorhynchus). We expanded upon a method for corticosteroid quantification by adding analytes and optimizing internal standard (IS) application.

View Article and Find Full Text PDF

Introduction: Load carriage is an inherent part of tactical operations. Critical speed (CS) has been associated with technical and combat-specific performance measures (e.g.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!