Background: LCP extra-articular distal humerus plate (LCPEA) designed by AO has been introduced as an anatomically shaped plate that improves the results of surgical fixation in extra-articular distal humeral shaft fractures. However, no study analyzed whether LCPEA matches humeral shaft forward flexion angulation (FFA).
Objective: The aims of this study were to evaluate the morphological discrepancies between LCPEA and the humeral shaft FFA in Chinese cadaveric dried adult humeri and to propose a further design of pre-contoured plates to accommodate the FFA.
Materials And Methods: Forty-four Chinese cadaveric dried adult humeri were used for this study. An eight-hole LCPEA was applied to the posterior aspect of the distal humerus according to the contour. Mismatches between the bone and the plate were recorded. The distance between the inner surface of the plate and the underlying humeral dorsal cortex was measured at the sites of mismatch. The humeral shaft FFA was measured from the intersection angle between tangent lines placed on the dorsal aspect of the 1/3 distal humeral shaft and the dorsal ridge of the 2/3 proximal humeral shaft. The location of the apex of the FFA was determined by measuring the distance from the most distal point of trochlea of humerus to the point of intersection of the FFA tangent lines. The distance was defined as forward flexion distance (FFD).
Results: Mismatch was found at the level of proximal 3-6 holes of LCPEA with an average distance of 6.9 ± 3.1 mm (range 2.3-14.0 mm) at the tip of the plate. The FFA was present in all specimens. The average FFA was 8.2° ± 2.2° (range 4°-13°), the average FFD was 99.9 ± 9.6 mm (range 79.2-117.9 mm), and the average ratio of FFD to humerus length was 0.33 ± 0.03 (range 0.27-0.39).
Conclusions: A rather consistent pattern of mismatch was found at the proximal part of LCPEA. An attempt to fit the plate to the bone at this level may cause a gap of the fracture at the opposite cortex. The main reason for the mismatch is the existence of the humeral shaft FFA. LCPEA is usually made a bend of about 8° between the fourth and the fifth dynamic-compression portion of the combination hole in the distal-to-proximal direction.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00590-014-1431-2 | DOI Listing |
Curr Rev Musculoskelet Med
January 2025
Department of Orthopaedic Surgery, Washington University in St. Louis, St. Louis, MO, USA.
Purpose Of Review: With the growing popularity and broadening indications for Reverse Shoulder Arthroplasty (RSA), increasing modularity in design and adjustments to each component can enhance postoperative range of motion (ROM), thus expanding treatment capabilities. This review outlines the advancements developed to optimize ROM through modifications in glenoid and humeral components and the integration of computational tools for surgical planning.
Recent Findings: Enhancements in glenoid component design aim to mitigate complications like scapular notching and improve ROM, particularly in abduction and external rotation.
J Orthop Surg Res
January 2025
Department of Orthopaedic Surgery, Kobe City Medical Center General Hospital, 2-1-1 Minatojima-minamimachi, Chuo-ku, Kobe, 650-0047, Japan.
Background: Although the Neer and AO/OTA classifications have been widely accepted, observer reliability studies of these two classifications have questioned their reliability and reproducibility to date. We developed an entirely new classification, the Mitsuzawa classification, for dislocated and displaced proximal humeral fractures and tested all three classifications for their intra- and interobserver reliability.
Methods: Two experienced shoulder surgeons and two orthopedic residents independently evaluated the Xray (xR) values of 100 proximal humeral fractures (PHFs).
Mymensingh Med J
January 2025
Dr Shah Md Atiqul Haque, Assistant Professor, Department of Anatomy, Mymensingh Medical College (MMC), Mymensingh, Bangladesh; E-mail:
The upper end of the humerus consists of three necks such as anatomical neck, surgical neck and morphological neck. The anatomical neck of the humerus is the area just below the head of the humerus. The surgical neck of the humerus is the area just below the greater and lesser tubercle of the humerus.
View Article and Find Full Text PDFJ Pediatr Orthop B
December 2024
Department of Orthopaedic Surgery, University of Arkansas for Medical Sciences, Little Rock, Arkansas, USA.
All-terrain vehicle (ATV) accidents frequently cause orthopedic injuries. Previous studies have reported the frequency of fractures in ATV injuries. No studies have provided detailed assessments of fracture patterns, types of operative intervention, or risks for multiple surgeries.
View Article and Find Full Text PDFMalays Orthop J
November 2024
Department of Orthopaedic Surgery, Japanese Red Cross Ashikaga Hospital, Tochigi, Japan.
Introduction: Antegrade intramedullary nail fixation for humeral shaft fractures yields satisfactory union rates. However, one of the related concerns is damage to the rotator cuff during nail insertion, which may affect long-term outcomes. The effect of a rotator cuff lesion on mid- and long-term shoulder outcomes remains unknown.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!