Development and validation of the pediatric AzBio sentence lists.

Ear Hear

1Department of Research and Technology, Advanced Bionics Corporation, Valencia, California, USA; 2Department of Speech and Hearing Sciences, Arizona State University, Tempe, Arizona, USA; 3Department of Hearing and Speech Sciences, Vanderbilt University, Nashville, Tennessee, USA; and 4Mayo Clinic, Rochester, Minnesota, USA.

Published: February 2015

Objectives: The goal of this study was to create and validate a new set of sentence lists that could be used to evaluate the speech-perception abilities of listeners with hearing loss in cases where adult materials are inappropriate due to difficulty level or content. The authors aimed to generate a large number of sentence lists with an equivalent level of difficulty for the evaluation of performance over time and across conditions.

Design: The original Pediatric AzBio sentence corpus included 450 sentences recorded from one female talker. All sentences included in the corpus were successfully repeated by kindergarten and first-grade students with normal hearing. The mean intelligibility of each sentence was estimated by processing each sentence through a cochlear implant simulation and calculating the mean percent correct score achieved by 15 normal-hearing listeners. After sorting sentences by mean percent correct scores, 320 sentences were assigned to 16 lists of equivalent difficulty. List equivalency was then validated by presenting all sentence lists, in a novel random order, to adults and children with hearing loss. A final-validation stage examined single-list comparisons from adult and pediatric listeners tested in research or clinical settings.

Results: The results of the simulation study allowed for the creation of 16 lists of 20 sentences. The average intelligibility of each list ranged from 78.4 to 78.7%. List equivalency was then validated, when the results of 16 adult cochlear implant users and 9 pediatric hearing aid and cochlear implant users revealed no significant differences across lists. The binomial distribution model was used to account for the inherent variability observed in the lists. This model was also used to generate 95% confidence intervals for one and two list comparisons. A retrospective analysis of 361 instances from 78 adult cochlear implant users and 48 instances from 36 pediatric cochlear implant users revealed that the 95% confidence intervals derived from the model captured 94% of all responses (385 of 409).

Conclusions: The cochlear implant simulation was shown to be an effective method for estimating the intelligibility of individual sentences for use in the evaluation of cochlear implant users. Furthermore, the method used for constructing equivalent sentence lists and estimating the inherent variability of the materials has also been validated. Thus, the AzBio Pediatric Sentence Lists are equivalent and appropriate for the assessment of speech-understanding abilities of children with hearing loss as well as adults for whom performance on AzBio sentences is near the floor.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3971099PMC
http://dx.doi.org/10.1097/AUD.0000000000000031DOI Listing

Publication Analysis

Top Keywords

cochlear implant
28
sentence lists
24
implant users
20
hearing loss
12
lists equivalent
12
lists
10
sentence
9
pediatric azbio
8
azbio sentence
8
implant simulation
8

Similar Publications

Speech Perception in Noise After Cochlear Implantation for Single-Sided Deafness: A Randomized Clinical Trial.

JAMA Otolaryngol Head Neck Surg

January 2025

Department of Otorhinolaryngology and Head & Neck Surgery, University Medical Center Utrecht, Utrecht University, Utrecht, the Netherlands.

Importance: There is a lack of high level of evidence studies comparing the effect of different treatment options for single-sided deafness (SSD).

Objective: To determine the effect of a cochlear implant (CI), bone conduction device (BCD), contralateral routing of signals hearing aid (CROS), and no treatment on speech perception in noise outcomes in patients with SSD.

Design, Setting, And Participants: In this single-center randomized clinical trial, adult patients with SSD were randomized into 3 groups: CI; a trial period with first a BCD on a headband and then a CROS; or a trial period with first a CROS and then a BCD on a headband.

View Article and Find Full Text PDF

When listening to speech under adverse conditions, listeners compensate using neurocognitive resources. A clinically relevant form of adverse listening is listening through a cochlear implant (CI), which provides a spectrally degraded signal. CI listening is often simulated through noise-vocoding.

View Article and Find Full Text PDF

Background: Pediatric cochlear implant (CI) recipients with cochlear malformations face challenges due to variable speech recognition outcomes.

Aims/objectives: This study assesses the predictive value of intraoperative electrically evoked compound action potential (eCAP) thresholds, residual hearing, age at implantation, Intelligent Quotient (IQ), and malformation type for speech recognition outcomes.

Material And Methods: A prospective cohort of 52 children (aged 1-4 years) with cochlear malformations who underwent CI between 2016 and 2024 was analyzed.

View Article and Find Full Text PDF

Former studies have established that individuals with a cochlear implant (CI) for treating single-sided deafness experience improved speech processing after implantation. However, it is not clear how each ear contributes separately to improve speech perception over time at the behavioural and neural level. In this longitudinal EEG study with four different time points, we measured neural activity in response to various temporally and spectrally degraded spoken words presented monaurally to the CI and non-CI ears (5 left and 5 right ears) in 10 single-sided CI users and 10 age- and sex-matched individuals with normal hearing.

View Article and Find Full Text PDF

Objectives: This study was designed to (1) compare preactivation and postactivation performance with a cochlear implant for children with functional preoperative low-frequency hearing, (2) compare outcomes of electric-acoustic stimulation (EAS) versus electric-only stimulation (ES) for children with versus without hearing preservation to understand the benefits of low-frequency acoustic cues, and (3) to investigate the relationship between postoperative acoustic hearing thresholds and performance.

Design: This was a prospective, 12-month between-subjects trial including 24 pediatric cochlear implant recipients with preoperative low-frequency functional hearing. Participant ages ranged from 5 to 17 years old.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!