Can a resident's publication record predict fellowship publications?

PLoS One

University of Maryland, Department of Medicine, Baltimore, Maryland, United States of America.

Published: January 2015

Background: Internal medicine fellowship programs have an incentive to select fellows who will ultimately publish. Whether an applicant's publication record predicts long term publishing remains unknown.

Methods: Using records of fellowship bound internal medicine residents, we analyzed whether publications at time of fellowship application predict publications more than 3 years (2 years into fellowship) and up to 7 years after fellowship match. We calculate the sensitivity, specificity, positive and negative predictive values and likelihood ratios for every cutoff number of application publications, and plot a receiver operator characteristic curve of this test.

Results: Of 307 fellowship bound residents, 126 (41%) published at least one article 3 to 7 years after matching, and 181 (59%) of residents do not publish in this time period. The area under the receiver operator characteristic curve is 0.59. No cutoff value for application publications possessed adequate test characteristics.

Conclusion: The number of publications an applicant has at time of fellowship application is a poor predictor of who publishes in the long term. These findings do not validate the practice of using application publications as a tool for selecting fellows.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3962333PMC
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0090140PLOS

Publication Analysis

Top Keywords

application publications
12
publication record
8
fellowship
8
internal medicine
8
long term
8
fellowship bound
8
time fellowship
8
fellowship application
8
years fellowship
8
receiver operator
8

Similar Publications

Production of HMF-derivatives from wine residues using Saccharomyces cerevisiae as whole-cell biocatalyst.

Bioresour Bioprocess

January 2025

CEB - Centre of Biological Engineering, University of Minho, Campus Gualtar, Braga, 4710-057, Portugal.

Background: There is an urgent need to develop bioprocesses independent of fossil resources to address resource depletion and mitigate environmental harm. Transitioning to a bio-based economy requires prioritizing chemical production processes that utilize renewable resources, ensuring sustainability and environmental responsibility. 5-Hydroxymethylfurfural (HMF) and its derivatives are promising building blocks, ranked among the top 12 bio-based molecules derived from biomass.

View Article and Find Full Text PDF

Microalgae-based flue gas CO sequestration for cleaner environment and biofuel feedstock production: a review.

Environ Sci Pollut Res Int

January 2025

Biorefinery and Bioenergy Research Laboratory, Centre for Plant and Environmental Biotechnology, Amity Institute of Biotechnology, Amity University Uttar Pradesh, Noida, 201313, India.

Anthropogenic CO emissions are the prime cause of global warming and climate change, promoting researchers to develop suitable technologies to reduce carbon footprints. Among various CO sequestration technologies, microalgal-based methods are found to be promising due to their easier operation, environmental benefits, and simpler equipment requirements. Microalgae-based carbon capture and storage (CCS) technology is essential for addressing challenges related to the use of industrial-emitted flue gases.

View Article and Find Full Text PDF

Plasmonic sensor design: Cu-SiO₂-Ni-black phosphorus for enhanced surface plasmon resonance in visible regime.

Mikrochim Acta

January 2025

Department Electronics and Communication Engineering, BKIT Dwarahat, Dwarahat, Uttarakhand, India, 263653.

A novel surface plasmon resonance (SPR) sensor is presented utilizing a BK7 prism, copper (Cu), silicon dioxide (SiO), nickel (Ni), and black phosphorus (BP) for enhanced biomolecule sensing in the refractive index (RI) range of 1.33 - 1.335.

View Article and Find Full Text PDF

Aim/hypothesis: Pilots with type 1 diabetes are required to perform capillary glucose monitoring regularly during flights. Continuous glucose monitoring (CGM) may be an effective and more practical alternative. This study aimed to assess the accuracy of CGM systems against self-monitoring of blood glucose (SMBG) during a hypobaric flight simulation.

View Article and Find Full Text PDF

Purpose: Low-dose CT (LDCT) screening effectively reduces lung adenocarcinoma (LUAD) mortality. However, accurately evaluating the malignant potential of indeterminate lung nodules remains a challenge. Carcinoembryonic antigen cell adhesion molecule 6 (CEACAM6), a potential biomarker for distinguishing benign pulmonary nodules from LUAD, may be leveraged for noninvasive positron emission tomography (PET) imaging to aid LUAD diagnosis.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!