A series of new hexadentate and pentadentate chelators were designed and synthesized as chelators of (64)Cu. The new pentadentate and hexadentate chelators contain different types of donor groups and are expected to form neutral complexes with Cu(II). The new chelators were evaluated for complex kinetics and stability with (64)Cu. The new chelators instantly bound to (64)Cu with high labeling efficiency and maximum specific activity. All (64)Cu-radiolabeled complexes in human serum remained intact for 2 days. The (64)Cu-radiolabeled complexes were further challenged by EDTA in a 100-fold molar excess. Among the (64)Cu-radiolabeled complexes evaluated, (64)Cu-complex of the new chelator E was well tolerated with a minimal transfer of (64)Cu to EDTA. (64)Cu-radiolabeled complex of the new chelator E was further evaluated for biodistribution studies using mice and displayed rapid blood clearance and low organ uptake. (64)Cu-chelator E produced a favorable in vitro and in vivo complex stability profiles comparable to (64)Cu complex of the known hexadentate NOTA chelator. The in vitro and in vivo data highlight strong potential of the new chelator E for targeted PET imaging application.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4139964 | PMC |
http://dx.doi.org/10.1016/j.bmc.2014.02.041 | DOI Listing |
Bioconjug Chem
March 2012
Department of Molecular Medicine, Kyungpook National University, Daegu 700-422, South Korea.
Ethylene cross-bridged cyclam with two acetate pendant arms, ECB-TE2A, is known to form the most kinetically stable (64)Cu complexes. However, its usefulness as a bifunctional chelator is limited because of its harsh radiolabeling conditions. Herein, we report new cross-bridged cyclam chelator for the development of ultrastable (64)Cu-radiolabeled bioconjugates.
View Article and Find Full Text PDFJ Med Chem
May 2007
Mallinckrodt Institute of Radiology, Washington University School of Medicine, St Louis, Missouri 63110, USA.
Copper-64, a positron emitter suitable for positron emission tomography (PET), demonstrates improved in vivo clearance when chelated by the cross-bridged tetraazamacrocycle CB-TE2A compared to TETA. Good in vivo clearance was also observed for 64Cu-CB-TE2A conjugated to a peptide, which converts one coordinating carboxylate pendant arm to an amide. To better understand the in vivo stability of peptide- conjugated CB-TE2A, cross-bridged monoamides were synthesized.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!