Clinical results of an EPID-based in-vivo dosimetry method for pelvic cancers treated by intensity-modulated radiation therapy.

Phys Med

INSERM, Imagerie cérébrale et handicaps neurologiques, UMR 825, F-31059 Toulouse, France; Université de Toulouse, UPS, INPT, LAPLACE Laboratoire Plasma et Conversion d'Energie, 118 route de Narbonne, F-31062 Toulouse Cedex 9, France; Université de Toulouse, UPS, Imagerie cérébrale et handicaps neurologiques, UMR 825, F-31059 Toulouse, France.

Published: September 2014

The purpose of our work was to investigate the feasibility of using an EPID-based in-vivo dosimetry method initially designed for conformal fields on pelvic dynamic IMRT fields. The method enables a point dose delivered to the patient to be calculated from the transit signal acquired with an electronic portal imaging device (EPID). After defining a set of correction factors allowing EPID pixel values to be converted into absolute doses, several tests on homogeneous water-equivalent phantoms were performed to estimate the validity of the method in reference conditions. The effects of different treatment parameters, such as delivered dose, field size dependence and patient thickness were also studied. The model was first evaluated on a group of 53 patients treated by 3D conformal radiotherapy (3DCRT) and then on 92 patients treated by IMRT, both for pelvic cancers. For each measurement, the dose was reconstructed at the isocenter (DREC) and compared with the dose calculated by our treatment planning system (DTPS). Excellent agreement was found between DREC and DTPS for both techniques. For 3DCRT treatments, the mean deviation between DREC and DTPS for the 211 in-vivo dose verifications was equal to -1.0  ±  2.2% (1SD). Concerning IMRT treatments, the averaged deviation for the 418 fields verified was equal to -0.3 ± 2.6% (1SD) proving that the method is able to reconstruct a dose for dynamic IMRT pelvic fields. Based on these results, tolerance criteria and action levels were established before its implementation in clinical routine.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ejmp.2014.02.003DOI Listing

Publication Analysis

Top Keywords

epid-based in-vivo
8
in-vivo dosimetry
8
dosimetry method
8
pelvic cancers
8
dynamic imrt
8
patients treated
8
imrt pelvic
8
drec dtps
8
dose
6
method
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!