A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Development of a highly sensitive and selective mercury optical sensor based on immobilization of bis(thiophenal)-4,4'-methylenedianiline on a PVC membrane. | LitMetric

A reversible optical sensor was fabricated for highly sensitive and selective determination of Hg(II) ions. The optode was prepared using a newly synthesized ionophore, bis(thiophenal)-4,4'-methylenedianiline, and ETH-5294 as a lipophilic H(+)-selective indicator in a plasticized PVC membrane. Different variables affect the optical signal such as pH and compositions of the membrane components were optimized. The spectrophotometric method (λmax 662 nm) was used for the determination of Hg(II). Under the optimum conditions, the optode has a wide linear dynamic range of 2.51×10(-13) to 1.02×10(-5) mol L(-1) Hg(II) with a detection limit as low as 3.43×10(-14) mol L(-1) and a response time of 90 s (for a highly diluted solution). The influence of potential interference ions on the Hg(II) determination was studied. The results showed that the prepared optical sensor was highly selective to Hg(II) ions so that it had no significant response to a wide variety of common metal ions. The response of the optode to Hg(II) is completely reversible and was lucratively applied for the determination of Hg(II) in different real samples.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.msec.2014.01.059DOI Listing

Publication Analysis

Top Keywords

optical sensor
12
determination hgii
12
highly sensitive
8
sensitive selective
8
pvc membrane
8
hgii ions
8
mol l-1
8
ions response
8
hgii
7
development highly
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!