A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Folate Profiling in Potato (Solanum tuberosum) Tubers by Ultrahigh-Performance Liquid Chromatography-Tandem Mass Spectrometry. | LitMetric

An ultrahigh-performance liquid chromatography-tandem mass spectrometry method was developed and validated for the profiling of six folate species in potatoes. The calibration curves cover a wide, linear range (the lower and upper limits of quantitation range between 0.22-0.24 and 216.07-242.28 μg/100 g of fresh weight), allowing sensitive determination in small amounts of potato flesh. With a single exception, the acceptance criteria for intra- and interday precision and accuracy were met: for all quality controls, the percent relative standard deviation and the percent bias were lower than 15% (or 20% at the lower limit of quantitation). Application of the method on tubers at different stages of maturation demonstrated the large variability within a single variety: the folate content and polyglutamylation rate varied between 10.35 and 24.01 μg/100 g of fresh weight and between 4.96% and 60.49%, respectively. Additionally, the two-dimensional folate profiling of mature tubers demonstrated an increase in folate from center to peel, combined with a stable species distribution and polyglutamylation rate.

Download full-text PDF

Source
http://dx.doi.org/10.1021/jf500753vDOI Listing

Publication Analysis

Top Keywords

folate profiling
8
ultrahigh-performance liquid
8
liquid chromatography-tandem
8
chromatography-tandem mass
8
mass spectrometry
8
μg/100 fresh
8
fresh weight
8
polyglutamylation rate
8
folate
5
profiling potato
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!