Background: It has recently been reported that reusable dispensers for surface disinfection tissues may be contaminated, especially with adapted Achromobacter species 3, when products based on surface-active ingredients are used. Fresh solution may quickly become recontaminated if dispensers are not processed adequately.
Methods: We evaluated the abilities of six manual and three automatic processes for processing contaminated dispensers to prevent recolonisation of a freshly-prepared disinfectant solution (Mikrobac forte 0.5%). Dispensers were left at room temperature for 28 days. Samples of the disinfectant solution were taken every 7 days and assessed quantitatively for bacterial contamination.
Results: All automatic procedures prevented recolonisation of the disinfectant solution when a temperature of 60-70°C was ensured for at least 5 min, with or without the addition of chemical cleaning agents. Manual procedures prevented recontamination of the disinfectant solution when rinsing with hot water or a thorough cleaning step was performed before treating all surfaces with an alcohol-based disinfectant or an oxygen-releaser. Other cleaning and disinfection procedures, including the use of an alcohol-based disinfectant, did not prevent recolonisation.
Conclusions: These results indicate that not all processes are effective for processing reusable dispensers for surface-disinfectant tissues, and that a high temperature during the cleaning step or use of a biofilm-active cleaning agent are essential.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3960927 | PMC |
http://dx.doi.org/10.3205/dgkh000229 | DOI Listing |
BMC Oral Health
January 2025
Department of Dental Science, Damascus University, Damascus, Syria.
Background: The smear layer formed during root canal instrumentation negatively affects root canal irrigation activity, which in turn can affect the treatment prognosis of endodontic treatment.
Aim: The aim of this study is to compare the efficiency of smear layer and debris removal in root canals using different irrigation protocols using scanning electron microscopy (SEM).
Materials And Methods: The quality of smear layer removal throughout the root canal was assessed in 30 intact extracted teeth divided into 3 groups according to the irrigation protocol: Group 1: 3% sodium hypochlorite (NaOCL) alternately with 17% ethylenediaminetetraacetic acetate (EDTA) was used.
Vet Res Commun
January 2025
Escola de Veterinária e Zootecnia, Universidade Federal de Goiás, Goiânia, Goiás, Brazil.
The aim of this study was to investigate whether Trypanosoma vivax is transmitted via rectal palpation in cattle, using the same glove with different blood scores, from an animal with an acute infection of this protozoan. In addition, the efficacy of iodine as disinfectant, together with water with or without the presence of feces, to prevent the transmission of T. vivax in cattle during the rectal palpation process was evaluated in the laboratory and animals.
View Article and Find Full Text PDFChemosphere
January 2025
Faculty of Engineering, Hokkaido University, N13W8, Sapporo, 060-8628, Japan. Electronic address:
Global concern regarding transformation products (TPs) derived from contaminants, including pesticides, in the environment and during water treatment has been growing markedly. In the present study, we investigated the anti-acetylcholinesterase (AChE) activity of an aqueous solution of the organophosphorus insecticide disulfoton, a toxicological endpoint for determining the acceptable daily intake of disulfoton, both in the presence and the absence of metabolism during chlorination. Disulfoton rapidly reacted with free chlorine and completely disappeared within 0.
View Article and Find Full Text PDFBMC Chem
January 2025
Nursing Department, State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, Key Laboratory of Oral Biomedicine Ministry of Education, Hubei Key Laboratory of Stomatology, School & Hospital of Stomatology, Wuhan University, Wuhan, Hubei Province, 430079, China.
Background: This work intended to assess the disinfection efficacy of hypochlorous acid (HA) and silver nanoparticles (AgNP) disinfectants in disinfecting the dental unit waterlines (DUWL) during comprehensive oral treatment and explore their potential applications in the oral medical environment.
Methods: Firstly, AgNP solution was prepared and evaluated through X-ray diffraction (XRD), field emission transmission electron microscope (FE-TEM), and stability tests. Subsequently, 15 dental units were selected and randomly assigned to three groups, each receiving a different disinfection method.
Heliyon
January 2025
African Centre of Excellence for Water and Environmental Research (ACEWATER), Redeemer's University, Osun State, Nigeria.
Environmental antibiotic residues (EARs) and antibiotic-resistant bacteria (ARB) are known to contribute to global antimicrobial resistance (AMR). This study investigated EAR levels in selected wells, river, abattoir wastewater, bottled water and sachet water from Ede, Nigeria. Ecological risk quotient (RQ) and health risk (Hazard quotient) of the levels of these EARs, ARB and multidrug-resistant bacteria (MDR) with their antibiotic resistance were calculated.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!