Inaccuracy of EEG electrode coordinates forms an error term in forward model generation and ultimate source reconstruction performance. This error arises from the combination of both intrinsic measurement noise of the digitization apparatus and manual coregistration error when selecting corresponding points on anatomical MRI volumes. A common assumption is that such an error would lead only to displacement of localized sources. Here, we measured electrode positions on a 3D-printed full-scale replica head, using three different techniques: a fringe projection 3D scanner, a novel "Flying Triangulation" 3D sensor, and a traditional electromagnetic digitizer. Using highly accurate fringe projection data as ground truth, the Flying Triangulation sensor had a mean error of 1.5 mm while the electromagnetic digitizer had a mean error of 6.8 mm. Then, again using the fringe projection as ground truth, individual EEG simulations were generated, with source locations across the brain space and a range of sensor noise levels. The simulated datasets were then processed using a beamformer in conjunction with the electrode coordinates registered with the Flying Triangulation and electromagnetic digitizer methods. The beamformer's output SNR was severely degraded with the digitizer-based positions but less severely with the Flying Triangulation coordinates. Therefore, the seemingly innocuous error in electrode registration may result in substantial degradation of beamformer performance, with output SNR penalties up to several decibels. In the case of low-SNR signals such as deeper brain structures or gamma band sources, this implies that sensor coregistration accuracy could make the difference between successful detection of such activity or complete failure to resolve the source.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3949288PMC
http://dx.doi.org/10.3389/fnins.2014.00042DOI Listing

Publication Analysis

Top Keywords

fringe projection
12
electromagnetic digitizer
12
flying triangulation
12
eeg electrode
8
error
8
source reconstruction
8
reconstruction performance
8
electrode coordinates
8
ground truth
8
output snr
8

Similar Publications

This paper presents an effective three-dimensional (3D) surface reconstruction technique aimed at profiling composite surfaces with both specular and diffuse reflectance. Three-dimensional measurements based on fringe projection techniques perform well on diffuse reflective surfaces; however, when the measurement targets contain both specular and diffuse components, the efficiency of fringe projection decreases. To address this issue, the proposed technique integrates digital holography into the fringe projection setup, enabling the simultaneous capture of both specular and diffuse reflected light in the same optical path for full-field surface profilometry.

View Article and Find Full Text PDF

3D printing is an indispensable technology in modern life and is widely used in aerospace, exoskeleton, and architecture. The increasing accuracy requirements of 3D printed objects in these fields require high-precision measurement methods to obtain accurate data. Based on the precision measurement requirements, in this study, a fast multifrequency phase unwrapping method based on 3D printing object appearance acquisition is proposed.

View Article and Find Full Text PDF

Phase unwrapping is crucial in fringe projection profilometry (FPP) 3D measurement. However, achieving efficient and robust phase unwrapping remains a challenge, particularly when dealing with high-frequency fringes to achieve high accuracy. Existing methods rely on heavy fringe projections, inevitably sacrificing measurement efficiency.

View Article and Find Full Text PDF

Calculation of Fringe Angle with Enhanced Phase Sensitivity and 3D Reconstruction.

Sensors (Basel)

November 2024

Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China.

In the field of fringe projection profilometry, phase sensitivity is a critical factor influencing the precision of object measurements. Traditional techniques that employ basic horizontal or vertical fringe projection often do not achieve optimal levels of phase sensitivity. The identification of the fringe angle that exhibits optimal phase sensitivity has been a significant area of research.

View Article and Find Full Text PDF

Limits in the Perception of Facial Symmetry-A Prospective Study.

J Pers Med

November 2024

Department of Maxillofacial Surgery, University of Münster, Albert-Schweitzer-Campus 1, Building W30, 48149 Münster, Germany.

It is generally accepted that the symmetry of the face plays a significant role in the visual perception of its attractiveness. Therefore, its objective assessment could be useful for individual therapy planning. However, there is an ongoing debate about whether completely symmetrical faces are less attractive than those with minor deviations.

View Article and Find Full Text PDF