Monte Carlo modeling of carbon dioxide adsorption in porous aromatic frameworks.

Langmuir

Dipartimento di Scienze e Innovazione Tecnologica (DISIT), Centro Interdisciplinare Nano-SiSTeMI, Università del Piemonte Orientale, via T. Michel 11, I-15121, Alessandria, Italy.

Published: April 2014

The adsorption isotherms of CO2 in several porous aromatic frameworks (PAFs) have been simulated with Grand Canonical Monte Carlo technique, to support the synthesis of new materials for efficient carbon dioxide capture and storage. The simulations covered the 0-60 bar pressure range and were repeated at 273, 298, and 323 K. The force field employed in the simulations was optimized to fit the correct behavior of the free gas and to reproduce the CO2-phenyl interactions computed at high quantum mechanical level. PAFs are based on the diamond structure, with polyaromatic chains inserted in C-C bonds. We examined four PAF-30n (n being the number of phenyl rings in the aromatic linkers), finding that PAF-302 is overall the best performing, although PAF-301 provides higher adsorbed densities at very low pressure. The CO2 adsorption then was simulated in a number of modified PAF-302, with different functional groups (aminomethane, toluene, pyridine, and imidazole) attached to the phenyl chains; different degrees of substitution (25%, 50%, and 100% derivatized rings) were considered. The effects of functionalization and the dependence on the substitution degree are carefully discussed, to determine the most promising materials at low, intermediate, and high pressures.

Download full-text PDF

Source
http://dx.doi.org/10.1021/la500111aDOI Listing

Publication Analysis

Top Keywords

monte carlo
8
carbon dioxide
8
porous aromatic
8
aromatic frameworks
8
carlo modeling
4
modeling carbon
4
dioxide adsorption
4
adsorption porous
4
frameworks adsorption
4
adsorption isotherms
4

Similar Publications

Background: Online adaptive radiotherapy (OART) and rapid quality assurance (QA) are essential for effective heavy ion therapy (HIT). However, there is a shortage of deep learning (DL) models and workflows for predicting Monte Carlo (MC) doses in such treatments.

Purpose: This study seeks to address this gap by developing a DL model for independent MC dose (MCDose) prediction, aiming to facilitate OART and rapid QA implementation for HIT.

View Article and Find Full Text PDF

Although deterministic analysis can provide initial insights into slope stability, there is no way to reflect the true distribution of soil properties within a slope. To further investigate the effects of the spatial variability of soil properties on the stability and failure mechanism of slope under different foundation types, this study develops a framework combining simple limit equilibrium method (LEM), Monte Carlo Simulation (MCS), and random field to incorporate these factors into slope probabilistic stability analysis. The slope models of two typical foundations (e.

View Article and Find Full Text PDF

Nitrate (NO) pollution in groundwater is a worldwide environmental issue, particularly in developed planting-breeding areas where there is a substantial presence of nitrogen-related sources. Here, we explored the key sources and potential health risks of NO in a typical planting-breeding area in the North China Plain based on dual stable isotopes and Monte Carlo simulations. The analysis results revealed that the NO concentration ranged from 0.

View Article and Find Full Text PDF

Although sulfur-bearing minerals are valuable resources, they pose significant environmental risks to river ecosystems by releasing hazardous leachate. Accurately tracing these sources is crucial but challenging due to overlapping chemical signatures and pollutant transport dynamics in river systems. This study investigates seasonal and spatial variations in sulfate (SO) and trace element contributions in mining districts of the upper Nakdong River basin, South Korea.

View Article and Find Full Text PDF

The current study investigated the geometry, design and solid angle impacts on full energy peak efficiency (FEPE) of NaI(Tl) detectors for a line source. A line source is fabricated using 99mTc solution filled in a borosilicate glass tube of inner diameter 3 mm, tube wall thickness 2.5 mm and length 12.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!