With advances in joint preservation surgery that are intended to alter the course of osteoarthritis by early intervention, accurate and reliable assessment of the cartilage status is critical. Biochemically sensitive MRI techniques can add robust biomarkers for disease onset and progression, and therefore, could be meaningful assessment tools for the diagnosis and follow-up of cartilage abnormalities. T2* mapping could be a good alternative because it would combine the benefits of biochemical cartilage evaluation with remarkable features including short imaging time and the ability of high-resolution three-dimensional cartilage evaluation-without the need for contrast media administration or special hardware. Several in vitro and in vivo studies, which have elaborated on the potential of cartilage T2* assessment in various cartilage disease patterns and grades of degeneration, have been reported. However, much remains to be understood and certain unresolved questions have become apparent with these studies that are crucial to the further application of this technique. This review summarizes the principles of the technique and current applications of T2* mapping for articular cartilage assessment. Limitations of recent studies are discussed and the potential implications for patient care are presented.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00256-014-1852-3 | DOI Listing |
Int J Cardiovasc Imaging
January 2025
Cardiovascular MR R&D, Siemens Medical Solutions USA, Inc., Chicago, IL, USA.
Parametric mapping has become a standard of care technique for the non-invasive assessment of myocardial edema and fibrosis. Conventional MOLLI-based T1 mapping is susceptible to many confounding effects particularly in the pediatric population. The requirement for compliant breath holds is a major limitation for younger or more ill patients.
View Article and Find Full Text PDFClin Radiol
December 2024
Ankara University Faculty of Medicine, Department of Radiology, Ankara, Turkey. Electronic address:
Aim: The aim of the study was to evaluate and compare contrast-to-noise ratios (CNRs) and signal-to-noise ratios (SNRs) of pre- and postcontrast T1 maps, T2 maps, early and late gadolinium images in terms of visual assessment of cardiac thrombus, to see if maps can replace contrast-enhanced images for detection of cardiac thrombus.
Materials And Methods: T1, T2 maps, and postcontrast images of 22 patients with cardiac thrombus were retrospectively evaluated for SNR and CNR. SNR and CNR values of thrombus, blood pool, and myocardium measured at maps and contrast-enhanced images were compared with each other.
Cell Transplant
January 2025
Division of Rheumatology, Department of Internal Medicine, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea.
To assess the impact of a single intra-articular (IA) injection of bone marrow-derived mesenchymal stem cells (BM-MSCs) in patients with knee osteoarthritis (OA), a randomized, double-blind, placebo-controlled study was conducted. The study included 24 patients with knee OA who were randomly assigned to receive either a single IA injection of BM-MSCs or normal saline. Changes in the visual analog scale (VAS), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), and Knee Injury and Osteoarthritis Outcome Score (KOOS) after IA injection were assessed at 3, 6, 9, and 12 months.
View Article and Find Full Text PDFNMR Biomed
March 2025
Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China.
In clinical practice, particularly in neurology assessments, imaging multiparametric MR images with a single-sequence scan is often limited by either insufficient imaging contrast or the constraints of accelerated imaging techniques. A novel single scan 3D imaging method, incorporating Wave-CAIPI and MULTIPLEX technologies and named WAMP, has been developed for rapid and comprehensive parametric imaging in clinical diagnostic applications. Featuring a hybrid design that includes wave encoding, the CAIPIRINHA sampling pattern, dual time of repetition (TR), dual flip angle (FA), multiecho, and optional flow modulation, the WAMP method captures information on RF B1t fields, proton density (PD), T1, susceptibility, and blood flow.
View Article and Find Full Text PDFNMR Biomed
March 2025
Centre for Advanced Imaging, The University of Queensland, St Lucia, Queensland, Australia.
In this work, we introduce spatial and chemical saturation options for artefact reduction in magnetic resonance fingerprinting (MRF) and assess their impact on T and T mapping accuracy. An existing radial MRF pulse sequence was modified to enable spatial and chemical saturation. Phantom experiments were performed to demonstrate flow artefact reduction and evaluate the accuracy of the T and T maps.