Industrial single photon emission computed tomography (SPECT) is a promising diagnosis technique to investigate the dynamic behavior of process media. In the present study, a 12-gonal industrial SPECT system was developed using diverging collimators, and its performance was compared with those of hexagonal and 24-gonal systems. Of all of the systems, the 12-gonal type showed the best performance, providing (1) a detection-efficiency map without edge artifacts, (2) the best image resolution, and (3) reconstruction images that correctly furnish multi-source information. Based on the performance of the three different types of configurations, a SPECT system with 12-gonal type configuration was found most suitable for investigating and visualization of flow dynamics in industrial process systems.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.apradiso.2014.01.030 | DOI Listing |
EJNMMI Phys
January 2025
Department of Medical Radiation Physics and Nuclear Medicine, Karolinska University Hospital, Solna, Sweden.
Background: System calibration is essential for accurate SPECT/CT dosimetry. However, count losses due to dead time and pulse pileup may cause calibration errors, in particular for I, where high count rates may be encountered. Calibration at low count rates should also be avoided to minimise detrimental effects from e.
View Article and Find Full Text PDFPhys Med Biol
January 2025
Institute of Biomedical Engineering, Shenzhen Bay Laboratory, Guangqiao Load, Shenzhen, 518132, CHINA.
To develop and validate a novel multidimensional readout method that significantly reduces the number of readout channels in PET detectors while maintaining high spatial and energy performance. Approach: We arranged a 3×3×4 SiPM array in multiple dimensions and employed row/column/layer summation with a resistor-based splitting circuit. We then applied denoising methods to enhance the peak-to-valley ratio in the decoding map, ensuring accurate crystal-position determination.
View Article and Find Full Text PDFBMC Cardiovasc Disord
January 2025
Liver and Digestive Research Center, Research Institute for Health Development, Kurdistan University of Medical Sciences, Sanandaj, Iran.
Background: Covid-19 is a pandemic viral disease that directly or indirectly affects multiple organ systems, including the cardiovascular system. SPECT GATED MPI is a non-invasive nuclear imaging modality used to assess myocardial perfusion and function. The aim of this study was to evaluate the effect of Covid-19 pandemic on myocardial perfusion imaging in ischemic heart disease.
View Article and Find Full Text PDFJ Imaging Inform Med
January 2025
Department of Anesthesiology, E-Da Cancer Hospital, I-Shou University, Kaohsiung, Taiwan.
Parkinson's disease (PD), a degenerative disorder of the central nervous system, is commonly diagnosed using functional medical imaging techniques such as single-photon emission computed tomography (SPECT). In this study, we utilized two SPECT data sets (n = 634 and n = 202) from different hospitals to develop a model capable of accurately predicting PD stages, a multiclass classification task. We used the entire three-dimensional (3D) brain images as input and experimented with various model architectures.
View Article and Find Full Text PDFCureus
December 2024
Internal Medicine, Trinity Health Oakland Hospital, Pontiac, USA.
Cerebral venous thrombosis (CVT) is a rare and complex form of stroke, representing a small percentage of all stroke cases. The disease's clinical presentation is highly variable, involving a wide range of medical specialists due to its diverse manifestations. Over the past decade, significant advancements in understanding CVT have been made, particularly in light of the COVID-19 pandemic and subsequent vaccination efforts.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!