Poly(tetrafluoroethylene) (PTFE) latex particles have been analyzed and sorted according to size using asymmetric flow field flow fractionation (AF4) coupled with multiple-angle light scattering (MALS). Characterization of fractions by regular and depolarized dynamic light scattering confirmed that smaller particles elute prior to larger ones, as expected for field flow fractionation. The measured radii of the optically and geometrically anisotropic particles are consistent with those determined from transmission electron microscopy (TEM). A certain amount of heterogeneity remains in the fractions, but their uniformity for use as diffusion probes is improved. Full characterization of PTFE colloids will require a difficult assessment of the distribution, even within fractions, of the optical anisotropy. A general method to obtain number versus size distributions is presented. This approach is valid even when an online concentration detector is not available or ineffective. The procedure is adaptable to particles of almost any regular shape.

Download full-text PDF

Source
http://dx.doi.org/10.1021/la404902xDOI Listing

Publication Analysis

Top Keywords

field flow
12
flow fractionation
12
latex particles
8
asymmetric flow
8
flow field
8
light scattering
8
particles
5
flow
5
separation characterization
4
characterization polytetrafluoroethylene
4

Similar Publications

The big potassium (BK) channels remain open with a small limiting probability of ∼ 10 at minimal Ca and negative voltages < -100 mV. The molecular origin and functional significance of such "intrinsic opening" are not understood. Here we combine atomistic simulations and electrophysiological experiments to show that the intrinsic opening of BK channels is an inherent property of the vapor barrier, generated by hydrophobic dewetting of the BK inner pore in the deactivated state.

View Article and Find Full Text PDF

Introduction: This study evaluated the relationship between total plasma and free kidney concentrations of amphotericin B (AmB) in healthy and -infected Wistar rats using microdialysis and has the potential to significantly impact future research in this field and promote the development of antifungal drugs. The findings of this study, which show that plasma levels are a good predictor for AmB kidney concentrations and can be used to optimize its dosing regimen, underscore the importance of this research.

Methods: Microdialysis probe recovery rates were determined by dialysis and retrodialysis , as well as by retrodialysis .

View Article and Find Full Text PDF

Ensuring boar sperm quality before insemination is crucial for maximizing field fertility and efficient pig production. The computer-assisted sperm analysis (CASA) and fluorescence probes combined with flow cytometry (FC) are commonly used techniques for evaluating sperm kinematics and functions, closely related to animal fertility. However, their high cost and complex operations make it challenging to apply them in laboratories or pig breeding farms with limited resources.

View Article and Find Full Text PDF

Near-Field Mixing in a Coaxial Dual Swirled Injector.

Flow Turbul Combust

November 2024

Institut de Mécanique des Fluides de Toulouse, IMFT, CNRS, Université de Toulouse, Toulouse, France.

Improving mixing between two coaxial swirled jets is a subject of interest for the development of next generations of fuel injectors. This is particularly crucial for hydrogen injectors, where the separate introduction of fuel and oxidizer is preferred to mitigate the risk of flashback. Raman scattering is used to measure the mean compositions and to examine how mixing between fuel and air streams evolves along the axial direction in the near-field of the injector outlet.

View Article and Find Full Text PDF

Background: The fluorescent dye indocyanine green (ICG) has been used to identify anatomical structures intraoperatively in coronary artery bypass grafting (CABG). This study aimed to evaluate the feasibility of using ICG to assess graft patency and territorial distribution of myocardial reperfusion during CABG.

Methods: Porcine arrested hearts (n = 18) were used to evaluate territorial distribution of native coronary arteries and of a coronary bypass constructed with porcine saphenous vein graft (SVG) using ICG.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?