Avalanche current read-out circuit for low jitter parallel photon timing.

Electron Lett

M. Crotti, I. Rech, A. Gulinatti and M. Ghioni (Politecnico di Milano, DEIB, Milan, Italy).

Published: August 2013

We propose a novel circuit for single photon avalanche diode (SPAD) current read-out, for photon timing applications. The circuit consists of a single transistor trans-impedance amplifier with a GHz bandwidth: the feedback loop fixes the SPAD anode voltage and allows us to obtain a high time resolution with a very high equivalent current threshold (almost 700 μA). The trans-impedance stage is followed by a low pass filter that reduces the crosstalk of other on-chip detectors and makes the designed structure suitable for multi-detector systems. The discrete components prototype presented in this letter achieves a state-of-art resolution of 34.4 ps FWHM, presents negligible crosstalk between the different pixels and opens the way for the development of an integrated structure with a large number of channels.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3951173PMC
http://dx.doi.org/10.1049/el.2013.1879DOI Listing

Publication Analysis

Top Keywords

current read-out
8
photon timing
8
avalanche current
4
read-out circuit
4
circuit low
4
low jitter
4
jitter parallel
4
parallel photon
4
timing propose
4
propose novel
4

Similar Publications

Purpose: With the increasing use of proton therapy, there is a growing emphasis on including radiation quality, often quantified by linear energy transfer, as a treatment plan optimization factor. The Timepix detectors offer energy-sensitive particle tracking useful for the characterization of proton linear energy transfer. To improve the detector's performance in mixed radiation fields produced in proton therapy, we customized the detector settings and performed the per-pixel energy calibration.

View Article and Find Full Text PDF

Improving timing resolution of BGO for TOF-PET: a comparative analysis with and without deep learning.

EJNMMI Phys

January 2025

Sherbrooke Molecular Imaging Center and Department of Nuclear Medicine and Radiobiology, Université de Sherbrooke, 12th Avenue N, Sherbrooke, J1H 5N4, Québec, Canada.

Background: The renewed interest in BGO scintillators for TOF-PET is driven by the improved Cherenkov photon detection with new blue-sensitive SiPMs. However, the slower scintillation light from BGO causes significant time walk with leading edge discrimination (LED), which degrades the coincidence time resolution (CTR). To address this, a time walk correction (TWC) can be done by using the rise time measured with a second threshold.

View Article and Find Full Text PDF

Voice of a woman: influence of interaction partner characteristics on cycle dependent vocal changes in women.

Front Psychol

December 2024

Department for General Psychology and Cognitive Neuroscience, Institute of Psychology, Friedrich Schiller University, Jena, Germany.

Introduction: Research has shown that women's vocal characteristics change during the menstrual cycle. Further, evidence suggests that individuals alter their voices depending on the context, such as when speaking to a highly attractive person, or a person with a different social status. The present study aimed at investigating the degree to which women's voices change depending on the vocal characteristics of the interaction partner, and how any such changes are modulated by the woman's current menstrual cycle phase.

View Article and Find Full Text PDF

Graphene or MoS nanopores: pore adhesion and protein linearization.

Nanoscale

December 2024

Computational Biotechnology, RWTH Aachen University, Worringerweg 3, 52074 Aachen, Germany.

Nanopores drilled in materials can electrophoretically drive charged biomolecules to enable their detection. Here, we explore and compare two-dimensional nanopores, graphene and MoS, in order to unravel their advantages and disadvantages with regard to protein detection. We tuned the protein translocation and its dynamics by the choice and concentration of the surrounding solvent.

View Article and Find Full Text PDF

Plastic scintillation dosimeters (PSDs) are highly suitable for real-time dosimetry on the MR-linac. For optimal performance, the primary signal (scintillation) needs to be separated from secondary optical effects (Cerenkov, fluorescence and optical fiber attenuation). This requires a spectral separation approach and careful calibration.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!