Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
: In this report, the authors described the unusual case of a patient in whom the plasma phenytoin concentration was unexpectedly not detected on a particle-enhanced turbidimetric inhibition immunoassay (PETINIA) technique, a typical immunoassay for phenytoin. The plasma concentration was measured using PETINIA and high-performance liquid chromatography in a 69-year-old male patient treated with fosphenytoin intravenously at the standard dose for 7 days. Although the plasma concentration of phenytoin was below the limit of detection (<0.5 mcg/mL) on PETINIA after the administration of fosphenytoin, the trough plasma concentration was estimated to be between 5 and 10 mg/L on high-performance liquid chromatography. When the plasma concentrations of IgM and IgG were measured using an enzyme-linked immunosorbent assay, the plasma IgG level was within the reference range, whereas the plasma IgM level was 2-3 times higher than the upper limit of the reference range. We concluded that the PETINIA method yielded a possible false-negative result regarding the phenytoin level in this patient, perhaps because of some hindrance to the measurement process by IgM. This case suggests that false-negative results should be considered when therapeutic drug monitoring reveals abnormally low values using PETINIA and that it is necessary to evaluate the plasma IgM level.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/FTD.0000000000000067 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!