A diffusive gradients in thin films (DGT) device with polyquaternary ammonium salt (PQAS) as a novel binding agent (PQAS DGT) combined with graphite furnace atomic absorption spectrometry (GFAAS) was developed for the selective sampling and measurement of Cr (VI) in water. The performance of PQAS DGT was independent of pH 3-12 and ionic strength from 1 × 10(-3) to 1 molL(-1). DGT validation experiments showed that Cr (VI) was measured accurately as well as selectively by PQAS DGT, whereas Cr (III) was not determined quantitatively. Compared with diphenylcarbazide spectrophotometric method (DPC), the measurement of Cr (VI) with PQAS DGT was agreement with that of DPC method in the industrial wastewater. PQAS-DGT device had been successfully deployed in local freshwater. The concentrations of Cr (VI) determined by PQAS DGT coupled with GFAAS in Nuer River, Ling River and North Lake were 0.73 ± 0.09 μg L(-1), 0.50 ± 0.07 μg L(-1) and 0.61 ± 0.07 μg L(-1), respectively. The results indicate that PQAS DGT device can be used for the selective sampling and measurement Cr (VI) in water and its detection limit is lower than that of DPC method.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jhazmat.2014.02.022 | DOI Listing |
J Agric Food Chem
December 2014
College of Chemistry, Chemical Engineering and Food Safety, Research Institute of Food Science, and Food Safety Key Laboratory of Liaoning Province, Bohai University, Jinzhou, Liaoning 121013, People's Republic of China.
Diffusive gradients in thin-films (DGT) sampler with a polyquaternary ammonium salt (PQAS) aqueous solution as a binding phase and a dialysis membrane as a diffusive phase (PQAS DGT) was developed for the measurement of dissolved reactive phosphorus (DRP) in water. The performance of PQAS DGT was not dependent upon pH 3-10 and ionic strength from 1 × 10(-4) to 1 mol L(-1). The effective binding capacity of PQAS DGT containing 2.
View Article and Find Full Text PDFJ Hazard Mater
April 2014
College of Chemistry, Chemical Engineering and Food Safety, Bohai University, China; Research Institute of Food Science, Bohai University, China; Food Safety Key Lab of Liaoning Province, Jinzhou 121013, China. Electronic address:
A diffusive gradients in thin films (DGT) device with polyquaternary ammonium salt (PQAS) as a novel binding agent (PQAS DGT) combined with graphite furnace atomic absorption spectrometry (GFAAS) was developed for the selective sampling and measurement of Cr (VI) in water. The performance of PQAS DGT was independent of pH 3-12 and ionic strength from 1 × 10(-3) to 1 molL(-1). DGT validation experiments showed that Cr (VI) was measured accurately as well as selectively by PQAS DGT, whereas Cr (III) was not determined quantitatively.