AI Article Synopsis

  • The study aimed to evaluate the use of 3-dimensional transthoracic echocardiography (3D TTE) for visualizing the positions of cardiac device leads in relation to the tricuspid valve in patients with implantable devices like pacemakers.
  • Results showed that 3D TTE could effectively visualize lead positions in 90% of cases, revealing that leads often impinge on specific tricuspid valve leaflets, which can affect normal valve function.
  • Leads that interfered with the motion of the tricuspid valve leaflets were associated with increased severity of tricuspid regurgitation (TR), indicating a potential link between lead position and heart valve issues.

Article Abstract

Objectives: This study sought to: 1) determine the feasibility of using 3-dimensional transthoracic echocardiography (3D TTE) in patients with implantable cardiac resynchronization devices, pacemakers, and defibrillators to visualize the device leads in the right heart and their position relative to the tricuspid valve leaflets; 2) determine the prevalence of different lead positions; and 3) study the relationship between lead location and tricuspid regurgitation (TR) severity.

Background: Pacemaker, defibrillator, and cardiac resynchronization device implantation is currently guided by fluoroscopy, not allowing targeted lead positioning relative to the tricuspid valve leaflets. These leads have been reported to cause TR of variable degrees, but echocardiography is not routinely used to elucidate the mechanisms of lead interference with tricuspid valve leaflets in individual patients.

Methods: 3D TTE full-volume images of the right ventricle and/or zoomed images of the tricuspid valve were obtained in 121 patients with implanted devices. Images were viewed offline to determine the position of the device-lead relative to the tricuspid valve leaflets. Severity of TR was estimated on the basis of vena contracta measurements.

Results: 3D TTE clearly depicted lead position in 90% of patients. The right ventricular lead was impinging on either the posterior (20%) or septal (23%) leaflet or was not interfering with leaflet motion (53%) when positioned near the posteroseptal commissure or in the central portion of the tricuspid valve orifice. In the remaining patients, leads were impinging on the anterior leaflet (4%) or positioned in either the anteroposterior or anteroseptal commissure (3%). Leads interfering with normal leaflet mobility were associated with more TR than nonimpinging leads (vena contracta: median 0.62 cm [1st and 3rd quartiles: 0.51, 0.84 cm] vs. 0.27 cm [1st and 3rd quartiles: 0.00, 0.48 cm]; p < 0.001).

Conclusions: 3D TTE showed a clear association between device lead position and TR. To minimize TR induced by device-leads, 3D TTE guidance should be considered for placement in a commissural position.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jcmg.2013.11.007DOI Listing

Publication Analysis

Top Keywords

tricuspid valve
24
valve leaflets
16
relative tricuspid
12
device leads
8
tricuspid
8
tricuspid regurgitation
8
cardiac resynchronization
8
vena contracta
8
lead position
8
[1st 3rd
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!