Optimal conditions of LDR to protect the kidney from diabetes: exposure to 12.5 mGy X-rays for 8 weeks efficiently protects the kidney from diabetes.

Life Sci

Kosair Children's Hospital Research Institute, Department of Pediatrics, University of Louisville, Louisville, KY 40202, USA; Department of Radiation Oncology and Pharmacology, University of Louisville, Louisville, KY 40202, USA; Department of Toxicology, University of Louisville, Louisville, KY 40202, USA. Electronic address:

Published: May 2014

Aims: We reported the attenuation of diabetes-induced renal dysfunction by exposure to multiple low-dose radiation (LDR) at 25 mGy every other day by suppressing renal oxidative damage. We here explored the optimal conditions of LDR to protect the kidney from diabetes.

Main Methods: Male C57BL/6J mice with type 1 diabetes were induced with multiple injections of low-dose streptozotocin. Diabetic mice received whole body X-irradiation at a dose of 12.5, 25 or 50 mGy every other day for either 4 or 8 weeks. Age-matched normal mice were similarly irradiated at the dose of 25 mGy for 4 or 8 weeks. The renal function and histopathological changes were examined at the 4th and 8th weeks of the study.

Key Findings: Diabetes induced renal dysfunction is shown by the decreased creatinine and increased microalbumin in the urine. Renal oxidative damage, detected by protein nitration and lipid oxidation, and remodeling, reflected by increased expression of connective tissue growth factor, collagen IV and fibronectin, were significantly increased in diabetic mice. All these renal pathological and function changes in diabetic mice were significantly attenuated by exposure to LDR at all regimens, among which, however, exposure to LDR at 12.5 mGy for 8 weeks provided the best protective effect on the kidney of diabetic mice.

Significance: Our results suggest that whole-body LDR at 12.5 mGy every other day for 8 weeks is the optimal condition of LDR to protect the kidney from diabetes.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4066175PMC
http://dx.doi.org/10.1016/j.lfs.2014.02.037DOI Listing

Publication Analysis

Top Keywords

125 mgy
16
ldr protect
12
protect kidney
12
kidney diabetes
12
mgy day
12
diabetic mice
12
optimal conditions
8
conditions ldr
8
renal dysfunction
8
renal oxidative
8

Similar Publications

Assessing fetal radiation dose from iodine-125 seeds in pregnant breast cancer patients: an updated model.

Phys Med Biol

January 2025

Department of Medical Physics, Jeroen Bosch Ziekenhuis, Henri Dunantstraat 1, 's-Hertogenbosch, 5223GZ, NETHERLANDS.

The treatment of breast cancer during pregnancy requires careful consideration of consequences for both maternal and fetal health. In non-pregnant patients, the use of radioactive iodine-125 (125I)-seeds is standard practice for localising non-palpable breast tumors before breast-conserving surgery. However, the use of 125I-seeds in pregnant patients has been avoided due to concerns about fetal radiation exposure.

View Article and Find Full Text PDF

Assessment of Emphysema on X-ray Equivalent Dose Photon-Counting Detector CT: Evaluation of Visual Scoring and Automated Quantification Algorithms.

Invest Radiol

October 2024

From the Institute for Diagnostic and Interventional Radiology, University Hospital Zurich, University Zurich, Zurich, Switzerland (B.K., F.E., J.K., T.F., L.J.); Advanced Radiology Center, Department of Diagnostic Imaging and Oncological Radiotherapy, Fondazione Policlinico Universitario "A. Gemelli" IRCCS, Rome, Italy (C.S., A.R.L.); and Section of Radiology, Department of Radiological and Hematological Sciences, Università Cattolica del Sacro Cuore, Rome, Italy (A.R.L.).

Objectives: The aim of this study was to evaluate the feasibility and efficacy of visual scoring, low-attenuation volume (LAV), and deep learning methods for estimating emphysema extent in x-ray dose photon-counting detector computed tomography (PCD-CT), aiming to explore future dose reduction potentials.

Methods: One hundred one prospectively enrolled patients underwent noncontrast low- and chest x-ray dose CT scans in the same study using PCD-CT. Overall image quality, sharpness, and noise, as well as visual emphysema pattern (no, trace, mild, moderate, confluent, and advanced destructive emphysema; as defined by the Fleischner Society), were independently assessed by 2 experienced radiologists for low- and x-ray dose images, followed by an expert consensus read.

View Article and Find Full Text PDF

Objective: Robot-assisted (RA) technology is becoming more widely integrated and accepted in spine surgery. The authors sought to evaluate operative and patient-reported outcomes (PROs) in RA versus fluoroscopy-assisted (FA) pedicle screw placement during minimally invasive surgery (MIS) transforaminal lumbar interbody fusion (TLIF).

Methods: The authors retrospectively studied elective patients who underwent single- or multilevel MIS TLIF for degenerative indication using FA versus RA pedicle screw placement.

View Article and Find Full Text PDF

Comparison of the efficacy of S8 navigation system-assisted correction versus manual correction in the treatment of adolescent congenital scoliosis (ACS). A cohort study. A retrospective analysis was conducted on the clinical and imaging data of 48 patients with congenital scoliosis who were treated at the Honghui Hospital Affiliated with Xi'an Jiaotong University between May 2021 and January 2023.

View Article and Find Full Text PDF

Background: Photon counting detector (PCD) CT benefits from reduced noise compared with conventional energy-integrating detector (EID) CT, which should translate to improved image quality and reduced radiation exposure for pediatric patients undergoing chest CT with IV contrast.

Objective: To determine the differences in radiation exposure and image quality of PCD CT and EID CT in pediatric chest CT with intravenous (IV) contrast.

Materials And Methods: In this institutional review board-approved retrospective observational study, 20 scan pairs (20 PCD CT; 20 EID CT) for children who underwent chest CT with IV contrast on both a PCD CT (Siemens NAEOTOM Alpha) and an EID CT (Siemens SOMATOM Definition Edge or Force) within 12 months were reviewed independently by three pediatric radiologists for three subjective quality features on 5-point Likert scales: overall quality, small structure delineation, and motion artifact.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!