Distal radius volar locking plate design and associated vulnerability of the flexor pollicis longus.

J Hand Surg Am

Philadelphia Hand Center, Department of Orthopaedic Surgery, Thomas Jefferson University, Philadelphia, PA; Department of Orthopaedic Surgery, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand.

Published: May 2014

AI Article Synopsis

  • The study investigates the relationship between flexor pollicis longus (FPL) tendon ruptures and the prominence of different distal radius volar locking plates (VLPs) at the watershed line.
  • Researchers dissected ten specimens and analyzed various VLP designs to evaluate their positioning and surface areas impacting the FPL.
  • The findings show that while optimal plate placement is achievable, varying designs of VLPs still pose a risk of interference with the FPL, indicating the need for better implant design and surgical considerations.

Article Abstract

Purpose: Flexor pollicis longus (FPL) tendon rupture is a well-documented complication related to the use of distal radius volar locking plates (VLPs). The final common pathway of flexor tendon rupture appears to involve implants prominent at the watershed line. We hypothesized that significant differences in VLP prominence exist between various plate designs.

Methods: Ten fresh frozen specimens were dissected to identify the path of the FPL in relationship to the distal radius at the watershed line. Five VLP designs were fixed to each specimen based on their anatomic fit, and slid distally until the distal edge of the plate reached the watershed line. The position of each fixed plate was evaluated by fluoroscopy. We used a 3-dimensional laser scanner to create computer models. The total surface area of plate prominence volar to the watershed line and the prominent area beneath the FPL were measured in the axial plane using computer software.

Results: At the watershed line, the FPL was located at 54% of the maximal width of the radius, as measured from its volar-ulnar corner. There were no significant differences in the location of plate fixation on lateral view radiographs according to the classification of Soong et al. The mean total surface area of plate prominence was 36 mm(2). The mean prominent area beneath the FPL was 10 mm2. Significant differences in plate prominence were noted for various designs.

Conclusions: Despite optimal plate placement, various VLP designs were observed to have prominent profiles volar to the watershed line, to varying extents.

Clinical Relevance: The results raise concerns regarding interference between all of the analyzed VLP designs and the FPL. This study may help guide both implant design considerations and assist the surgeon in better understanding implant morphology as it relates to iatrogenic flexor tendon injury.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jhsa.2014.01.038DOI Listing

Publication Analysis

Top Keywords

distal radius
12
vlp designs
12
plate prominence
12
plate
9
radius volar
8
volar locking
8
tendon rupture
8
flexor tendon
8
total surface
8
surface area
8

Similar Publications

We report a series of 12 patients who developed early distal radioulnar joint subluxation after a distal radial fracture, not present on the initial radiographs. Early identification and management of this condition can give good clinical results. IV.

View Article and Find Full Text PDF

Treatment of anterior rim fractures of the distal radius with an anterior rim plate: A retrospective study.

J Hand Surg Eur Vol

January 2025

Department of Orthopedics, E-Da Hospital, I-Shou University/School of Medicine, College of Medicine, I-Shou University, Kaohsiung, Taiwan.

Treatment of distal radial fractures that include small anterior rim fragments can be difficult. We retrospectively reviewed 19 patients in whom an anterior rim plate with locking screws was used. After a median follow-up of 18 months (range 6-32; interquartile range (IQR) 14, 26), the median wrist flexion and extension arc was 70° (range 50-80; IQR 60, 70), the median grip strength was 80% of the contralateral side (range 52-104; IQR 77, 88), the median visual analogue scale score for pain was 0 (range 0-5; IQR 0, 1), the median disabilities of the arm, shoulder and hand score was 2 (range 0-59; IQR 0, 11) and the median modified Mayo wrist score was 80 (range 35-100; IQR 75, 85).

View Article and Find Full Text PDF

The main objectives of this work are to validate a 1D-0D unsteady solver with a distributed stenosis model for the patient-specific estimation of resting haemodynamic indices and to assess the sensitivity of instantaneous wave-free ratio (iFR) predictions to uncertainties in input parameters. We considered 52 patients with stable coronary artery disease, for which 81 invasive iFR measurements were available. We validated the performance of our solver compared to 3D steady-state and transient results and invasive measurements.

View Article and Find Full Text PDF

Background: Unstable diametaphyseal radius fractures (DMRFs) can be prone to complications, and treatment strategies are heterogeneous. Studies are difficult to interpret as definitions of the diametaphyseal junction zone (DMJZ) are impractical for clinical use, imprecise, or prone to error.

Methods: We introduce the forearm fracture index (FFI) to define DMRFs in radiographs and ultrasound.

View Article and Find Full Text PDF

Background: Early-term complications may not predict long-term success after adult cervical deformity (ACD) correction.

Objective: Evaluate whether optimal realignment results in similar rates of perioperative complications but achieves longer-term cost-utility.

Study Design: Retrospective cohort study.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!