Double Ring Array Catheter for In Vivo Real-Time 3D Ultrasound.

Ultrason Imaging

Department of Biomedical Engineering, Duke University, Durham, NC, USA.

Published: July 2014

We developed new forward-viewing matrix transducers consisting of double ring arrays of 118 total PZT elements integrated into catheters used to deploy medical interventional devices. Our goal is 3D ultrasound guidance of medical device implantation to reduce x-ray fluoroscopy exposure. The double ring arrays were fabricated on inner and outer custom polyimide flexible circuits with inter-element spacing of 0.20 mm and then wrapped around an 11 French (Fr) catheter to produce a 15 Fr catheter (outer diameter [O.D.]). We used a braided cabling technology to connect the elements to the Volumetrics Medical Imaging (VMI) real-time 3D ultrasound scanner. Transducer performance yielded an average -6 dB fractional bandwidth of 49% ± 11% centered at 4.4 MHz for 118 elements. Real-time 3D cardiac scans of the in vivo pig model yielded good image quality including en face views of the tricuspid valve and real-time 3D guidance of an endo-myocardial biopsy catheter introduced into the left ventricle.

Download full-text PDF

Source
http://dx.doi.org/10.1177/0161734614523738DOI Listing

Publication Analysis

Top Keywords

double ring
12
real-time ultrasound
8
ring arrays
8
ring array
4
catheter
4
array catheter
4
catheter vivo
4
real-time
4
vivo real-time
4
ultrasound developed
4

Similar Publications

Novel hybrid system based on carboxymethyl chitosan hydrogel encapsulating drug loaded nanoparticles for prolonged release of Vancomycin in the treatment of bacterial infection.

J Pharm Sci

January 2025

Institut Europeen des Membranes, IEM, UMR 5635, Univ Montpellier, CNRS, ENSCM, 34095, Montpellier, France. Electronic address:

Current bacterial infections clinical treatments, such as intravenous antibiotic administration and local injection, suffer from short action duration, repeated administrations, and severe cell toxicity. To address these limitations, it is imperative to develop sustained drug release system with prolonged antimicrobial effects. In this work, a hybrid system was prepared using EDC/NHS catalyzed crosslinking-based carboxymethyl chitosan (CMCS) hydrogel as a carrier to encapsulate biodegradable nanoparticles (NPs) loaded with vancomycin, an efficient antibacterial drug.

View Article and Find Full Text PDF

Quantifying ecosystem services provided by mobile species like insectivorous bats remains a challenge, particularly in understanding where and how these services vary over space and time. Bats are known to offer valuable ecosystem services, such as mitigating insect pest damage to crops, reducing pesticide use, and reducing nuisance pest populations. However, determining where bats forage is difficult to monitor.

View Article and Find Full Text PDF

We present a novel approach to realize three-dimensional (3D) matter wave solitons (MWSs) transformation between different optical potential wells by manipulating their depths and centers. The 3D MWSs are obtained by the square operator method, and transformed to other types (elliptical/ring/necklace) by performing time evolution with the split-step Fourier method. The effectiveness and reliability of our approach is demonstrated by comparing the transformed solitons with those obtained iteratively using the square operator method.

View Article and Find Full Text PDF

Introduction: As a result of increased incidence of anterior cruciate ligament (ACL) injury in young athletes, there is a rise in the indications surgical ACL reconstruction procedures. The value of anterolateral ligament (ALL) reconstruction emerges as a proposed solution to prevent graft failures and improve stability in this high demanding category of patients. The purpose of this study is to present our experience with a novel hamstring auto-grafting technique, the single antegrade sling graft (SASG), for combined reconstruction of both ACL and ALL using autologous gracilis (GR) and semitendinosus (ST) grafts utilizing a single femoral tunnel and double tibial tunnels.

View Article and Find Full Text PDF

Larvae of the flesh fly, Sarcophaga similis exhibit photoperiodic responses to control pupal diapause. Although the external coincidence model is applicable to S. similis photoperiodism, it remains unknown how the circadian clock system integrates day-length information.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!