To compare the levels of agreement and the survival rates of sealant retention for different sealing materials over a 2-year period assessed using the visual clinical examination and replica methods, sealant retention data were obtained by visual clinical examination and from replicas of the same sealed tooth at baseline and at 0.5-, 1- and 2-year evaluation points in 407 children and were compared for agreement using kappa coefficients. Survival curves of retained sealants on occlusal surfaces were created using modified categorisation (fully retained sealants and those having all pits and fissures partly covered with the sealant material versus completely lost sealants that included pit and fissure systems that had ≥1 pit re-exposed) according to the Kaplan-Meier method. The kappa coefficient for the agreement between both assessment methods over the three evaluation time points combined was 0.38 (95% confidence interval (CI): 0.35-0.41). More sealant retention was observed from replicas than through visual clinical examination. Cumulative survival curves at the three evaluation times were not statistically significantly higher when assessed from replicas (P=0.47). Using the replica method, more retained sealant material was observed than through visual clinical examination during the 2-year period. This finding did not result in a difference in the survival rates of sealants assessed by the two assessment methods. When replicas cast in die stone are used for assessing sealant retention, the level of reliability of the data is higher than that of data obtained through the commonly used visual clinical examination, particularly if such assessments are conducted over time.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5130059PMC
http://dx.doi.org/10.1038/ijos.2014.8DOI Listing

Publication Analysis

Top Keywords

visual clinical
24
clinical examination
24
sealant retention
20
2-year period
12
examination replica
8
replica method
8
survival rates
8
survival curves
8
retained sealants
8
sealant material
8

Similar Publications

Background: Detecting kidney trauma on CT scans can be challenging and is sometimes overlooked. While deep learning (DL) has shown promise in medical imaging, its application to kidney injuries remains underexplored. This study aims to develop and validate a DL algorithm for detecting kidney trauma, using institutional trauma data and the Radiological Society of North America (RSNA) dataset for external validation.

View Article and Find Full Text PDF

Background: Crohn's disease (CD) is a chronic, recurrent gastrointestinal disorder characterized by a complex etiology. Among its perianal complications, anal fistulas represent a challenging comorbidity. With the increase of surgical options, a comprehensive bibliometric analysis was deemed necessary to consolidate the vast array of research in this field.

View Article and Find Full Text PDF

Importance: Pediatric peripheral intravenous catheter (PIVC) insertion can be difficult and time-consuming, frequently requiring multiple insertion attempts and often resulting in increased anxiety, distress, and treatment avoidance among children and their families. Ultrasound-guided PIVC insertion is a superior alternative to standard technique (palpation and visualization) in high-risk patients.

Objective: To compare first-time insertion success of PIVCs inserted with ultrasound guidance compared with standard technique (palpation and visualization) across all risk categories in the general pediatric hospital population.

View Article and Find Full Text PDF

Virtual 3D reconstruction of complex congenital cardiac anatomy from 3D rotational angiography.

3D Print Med

January 2025

Department of Pediatric Cardiology, The Heart Institute, University of Colorado, Children's Hospital Colorado, 13123 E 16th Ave B100, 80045, Aurora, CO, USA.

Background: Despite advancements in imaging technologies, including CT scans and MRI, these modalities may still fail to capture intricate details of congenital heart defects accurately. Virtual 3D models have revolutionized the field of pediatric interventional cardiology by providing clinicians with tangible representations of complex anatomical structures. We examined the feasibility and accuracy of utilizing an automated, Artificial Intelligence (AI) driven, cloud-based platform for virtual 3D visualization of complex congenital heart disease obtained from 3D rotational angiography DICOM images.

View Article and Find Full Text PDF

The aim of this study was to compare the effectiveness of different types of low level laser treatment (LLLT) in reducing pain levels, changing oxygen saturation and bite force in patients with myofacial pain syndrome (MPS). 45 patients were randomly assigned to three groups: Group 1 (GRR laser, n = 15) received LLLT with Gallium-Aluminium-Arsenide (GaAlAs) diode laser with a wavelength of 904 nm and red laser with a wavelength of 650 nm over masseter muscle region. Group 2 (Nd: YAG laser, n = 15) were treated with Neodymium-doped Yttrium Aluminium Garnet laser with a wavelength of 1064 nm and the same protocol with Nd: YAG laser was performed in the Group 3 (placebo, n = 15) using sham device.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!