Background: The increasing importance of anti-Müllerian hormone (AMH) for the assessment of ovarian reserve requires accurate AMH measurements. There have been conflicting results about the reliability of currently existing manual AMH assays.
Methods: Development of a high sensitive, fast and fully automated AMH assay on the Elecsys®/cobas e electrochemiluminescence immunoassay platform.
Results: Elecsys® AMH is a monoclonal two-site assay used to measure AMH in 50 µL of serum or lithium heparin plasma in about 18 min. Its measuring range is from 0.01 to 23 ng/mL. The assay detects primarily 140 kDa total AMH (proAMH and AMHN,C). Standardization was against the Beckman AMH Gen II. Recovery against the highly cited Immunotech calibration was about 90%. Within-run imprecision coefficient of variation (CV) calculated on 10 serum samples were between 0.5% and 1.8%. Repeatability and intermediate precision calculated on 14 serum samples ranged from 2.6% to 1.7% and 2.9% to 2.1%, respectively. Limit of detection (LoD) [limit of quantitation (LoQ)] was 0.01 ng/mL (0.03 ng/mL). Percent recovery in dilution studies was <10% and after mixing of high and low AMH pools 94% to 103%. Elecsys® AMH, when compared to revised AMH Gen II (or Ansh Labs ultrasensitive AMH ELISA) using 57 female serum samples yielded a correlation coefficient of 0.98 (0.97) and a slope of 0.81 (0.73). There was no evidence for sample instability or variability. Samples stored at 20-25 °C or 2-8 °C up to 7 days showed no significant storage issues. Freeze-thaw cycles or sample storage at -20 °C and -80 °C for up to 9 months was without any effect on measured AMH.
Conclusions: Availability of an automated Elecsys® AMH assay offers an attractive alternative to the current manual AMH assays.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1515/cclm-2014-0022 | DOI Listing |
Oncol Lett
March 2025
Department of Imaging, The Affiliated Hospital of Beihua University, Jilin, Jilin 132011, P.R. China.
Contrast-enhanced ultrasonography (CEUS), a newly developed imaging technique, holds certain value in differentiating benign from malignant tumors. Additionally, serum tumor markers also exhibit significant clinical importance in the diagnosis and monitoring of malignant tumors. Reports have indicated abnormal expression of HER-2, CA153 and sE-cad in breast cancer.
View Article and Find Full Text PDFAsian J Transfus Sci
December 2024
HORIBA India Pvt. Ltd, HORIBA ABX SAS, Montpellier, France.
Background And Objectives: Objective of the study is to explore the possibility of utilization of seven part fully automated hematology analyzer for enumeration of residual leukocytes (residual white blood cells [rWBCs]) in leukoreduced packed red cells (LR-PRCs) prepared from whole blood at a blood center as an alternate to the gold standard method, flow cytometry. In this study, we evaluate the performance characteristic of hematology analyzer against flow cytometry for the estimation of rWBCs in 39 LR-PRC units.
Materials And Methods: PRCs prepared from whole blood donations by 39 donors were leukoreduced and their volumes were noted.
Cochrane Database Syst Rev
January 2025
Behaviour and Health Research Unit, Department of Public Health and Primary Care, University of Cambridge, Cambridge, UK.
Background: Overconsumption of food and consumption of any amount of alcohol increases the risk of non-communicable diseases. Calorie (energy) labelling is advocated as a means to reduce energy intake from food and alcoholic drinks. However, there is continued uncertainty about these potential impacts, with a 2018 Cochrane review identifying only a small body of low-certainty evidence.
View Article and Find Full Text PDFNat Commun
January 2025
Princess Margaret Cancer Centre, 101 College Street, Toronto, ON, Canada.
Deep learning has proven capable of automating key aspects of histopathologic analysis. However, its context-specific nature and continued reliance on large expert-annotated training datasets hinders the development of a critical mass of applications to garner widespread adoption in clinical/research workflows. Here, we present an online collaborative platform that streamlines tissue image annotation to promote the development and sharing of custom computer vision models for PHenotyping And Regional Analysis Of Histology (PHARAOH; https://www.
View Article and Find Full Text PDFBrief Bioinform
November 2024
Department of Electrical Engineering and Computer Science, University of Missouri, Columbia, MO 65211, United States.
Cryo-electron microscopy (cryo-EM) has revolutionized structural biology by enabling the determination of high-resolution 3-Dimensional (3D) structures of large biological macromolecules. Protein particle picking, the process of identifying individual protein particles in cryo-EM micrographs for building protein structures, has progressed from manual and template-based methods to sophisticated artificial intelligence (AI)-driven approaches in recent years. This review critically examines the evolution and current state of cryo-EM particle picking methods, with an emphasis on the impact of AI.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!