A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The role of a simulator-based course in coronary angiography on performance in real life cath lab. | LitMetric

Background: The aim of this study was to explore if a course consisting of lectures combined with simulator training in coronary angiography (CA) could accelerate the early learning curve when performing CA on patients.Knowledge in performing CA is included in the curriculum for the general cardiologist. The method, according to American College of Cardiology and European Society of Cardiology guidelines, for this training is not well defined but simulator training is proposed to be an option. However, the transfer effect from a CA simulator to performance in real world cath lab is not validated.

Methods: Fifty-four residents without practical skills in CA completed the course and 12 continued to training in invasive cardiology. These residents were tracked in the Swedish Coronary Angiography and Angioplasty Registry and compared to a control group of 46 novel operators for evaluation of performance metrics. A total of 4472 CAs were analyzed.

Results: Course participants demonstrated no consistent acceleration in the early learning curve in real world cath lab. They had longer fluoroscopy time compared to controls (median 360 seconds (IQR 245-557) vs. 289 seconds (IQR 179-468), p < 0.001). Safety measures also indicated more complications appearing at the ward, in particular when using the femoral approach (6.25% vs. 2.53%, p < 0.001).

Conclusions: Since the results of this retrospective non-randomized study were negative, the role of a structured course including simulator training for skills acquisition in CA is still uncertain. Randomized transfer studies are warranted to justify further use of simulators for training in CA.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3995776PMC
http://dx.doi.org/10.1186/1472-6920-14-49DOI Listing

Publication Analysis

Top Keywords

coronary angiography
12
cath lab
12
simulator training
12
performance real
8
early learning
8
learning curve
8
real cath
8
seconds iqr
8
training
6
course
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!