A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Mass spectrometry imaging of surface lipids on intact Drosophila melanogaster flies. | LitMetric

Mass spectrometry imaging of surface lipids on intact Drosophila melanogaster flies.

J Mass Spectrom

Institute of Organic Chemistry and Biochemistry, Academy of Science of the Czech Republic, v. v. i., Flemingovo nám. 2, CZ-166 10, Prague 6, Czech Republic; Department of Analytical Chemistry, Faculty of Science, Charles University in Prague, Hlavova 2030/8, CZ-128 43, Prague 2, Czech Republic; Max Planck Institute for Chemical Ecology, Hans-Knöll-Straße 8, D-07745, Jena, Germany.

Published: March 2014

The spatial distribution of neutral lipids and semiochemicals on the surface of six-day-old separately reared naive Drosophila melanogaster flies has been visualized and studied using matrix-assisted laser desorption/ionization-time of flight (MALDI-TOF) mass spectrometry and laser-assisted desorption/ionization (LDI)-TOF imaging (MSI). Metal targets were designed for two-dimensional MSI of the surface of 3-D biological objects. Targets with either simple grooves or profiled holes designed to accurately accommodate the male and female bodies were fabricated. These grooves and especially holes ensured correct height fixation and spatial orientation of the flies on the targets after matrix application and sample drying. For LDI-TOF to be used, the flies were arranged into holes and fixed to a plane of the target using fast-setting glue. In MALDI-TOF mode, the flies were fixed as above and sprayed with a lithium 2,5-dihydroxybenzoate matrix using up to 100 airbrush spray cycles. The scanning electron microscopy images revealed that the deposits of matrix were homogenous and the matrix formed mostly into the clusters of crystals (40-80 µm) that were separated from each other by an uncovered cuticle surface (30-40 µm). The MSI using target with profiled holes provided superior results to the targets with simple grooves, eliminating the ion suppression/mass deviation due to the 3-D shape of the flies. Attention was paid to neutral lipids and other compounds including the male anti-attractant 11-cis-vaccenyl acetate for which the expected distribution with high concentration on the tip of the male abdomen was confirmed. The red and blue mass shift (PlusMinus1 colour scale) was observed associated with mass deviation predominantly between ±0.2 and 0.3 Da. We use in-house developed software for mass recalibration, to eliminate the mass deviation effects and help with the detection of low-intensity mass signals.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jms.3331DOI Listing

Publication Analysis

Top Keywords

mass spectrometry
8
drosophila melanogaster
8
melanogaster flies
8
neutral lipids
8
targets simple
8
simple grooves
8
profiled holes
8
mass deviation
8
mass
7
flies
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!