Electroencephalography (EEG) and magnetoencephalography (MEG) are the two modalities for measuring neuronal dynamics at a millisecond temporal resolution. Different source analysis methods, to locate the dipoles in the brain from which these dynamics originate, have been readily applied to both modalities alone. However, direct comparisons and possible advantages of combining both modalities have rarely been assessed during voluntary movements using coherent source analysis. In the present study, the cortical and sub-cortical network of coherent sources at the finger tapping task frequency (2-4 Hz) and the modes of interaction within this network were analysed in 15 healthy subjects using a beamformer approach called the dynamic imaging of coherent sources (DICS) with subsequent source signal reconstruction and renormalized partial directed coherence analysis (RPDC). MEG and EEG data were recorded simultaneously allowing the comparison of each of the modalities separately to that of the combined approach. We found the identified network of coherent sources for the finger tapping task as described in earlier studies when using only the MEG or combined MEG+EEG whereas the EEG data alone failed to detect single sub-cortical sources. The signal-to-noise ratio (SNR) level of the coherent rhythmic activity at the tapping frequency in MEG and combined MEG+EEG data was significantly higher than EEG alone. The functional connectivity analysis revealed that the combined approach had more active connections compared to either of the modalities during the finger tapping (FT) task. These results indicate that MEG is superior in the detection of deep coherent sources and that the SNR seems to be more vital than the sensitivity to theoretical dipole orientation and the volume conduction effect in the case of EEG.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3949988PMC
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0091441PLOS

Publication Analysis

Top Keywords

coherent sources
16
source analysis
12
finger tapping
12
tapping task
12
voluntary movements
8
network coherent
8
sources finger
8
eeg data
8
combined approach
8
meg combined
8

Similar Publications

Purpose: This study compares and evaluates the parameters of iridotrabecular contact (ITC) in patients with primary angle closure disease (PACD) with natural lenses and pseudophakia based on anterior segment imaging data from swept-source optical coherence tomography (SS-OCT).

Material And Methods: This retrospective study analyzed data from 92 patients aged 32 to 89 years, and included 56 patients with PACD (43 with natural lenses and 13 with pseudophakia) and 36 in the control group (21 with natural lenses and 15 with pseudophakia). All participants underwent SS-OCT (CASIA2; Tomey Corporation, Japan), which included an assessment of the ITC Index and ITC Area.

View Article and Find Full Text PDF

System Dynamics Modeling of Scale Formation in Membrane Distillation Systems for Seawater and RO Brine Treatment.

Membranes (Basel)

November 2024

Civil and Environmental Engineering, Kookmin University, 77 Jeongneung-ro, Seongbuk-gu, Seoul 136-702, Republic of Korea.

To overcome the limitations of traditional Reverse Osmosis (RO) desalination, Membrane Distillation (MD) has gained attention as an effective solution for improving the treatment of seawater and RO brine. Despite its potential, the formation of inorganic scales, particularly calcium sulfate (CaSO), continues to pose a major challenge. This research aims to explore the scaling mechanisms in MD systems through a combination of experimental analysis and dynamic modeling.

View Article and Find Full Text PDF

Relationship Between Short-Term Blood Pressure Variability and Choroidal-Retinal Thicknesses Assessed by Optical Coherence Tomography in Hypertensive Subjects.

J Pers Med

November 2024

Unit of Nephrology and Dialysis, Hypertension Excellence Centre, Department of Health Promotion, Mother and Child Care, Internal Medicine and Medical Specialties (PROMISE), Università di Palermo, 90128 Palermo, Italy.

The complications of hypertension depend not only on the mean blood pressure (BP) but also on its variability (BPV). Recent studies suggest that the choroid may serve as an indicator of systemic vascular damage. These studies have been made possible by the increased availability of optical coherence tomography (OCT).

View Article and Find Full Text PDF

This meta-analysis aims to evaluate the efficacy and safety of diabetic vitrectomy for treating tractional retinal detachment (TRD) by assessing visual acuity improvements, retinal reattachment success rates, and the frequency of postoperative complications. A comprehensive literature search identified 1,211 studies, 30 of which met the inclusion criteria and were analyzed. The meta-analyses were conducted via random effects models to account for heterogeneity.

View Article and Find Full Text PDF

Starting from the extension to complex arguments of the ordinary Fourier transform (FT) (due to Paley and Wiener) and from results concerning reproducing kernels in Hilbert spaces, we define a new, to the best of our knowledge, class of partially coherent planar sources presenting a structured degree of coherence. Such sources are shown to be of the Schell-model type as far as one of the transverse coordinates is concerned, while they depend on the average value of the orthogonal coordinate of the two points. Some examples are shown in detail, but the proposed approach can be easily extended to infinitely many other sources.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!