Otoacoustic emissions in newborn hearing screening: a systematic review of the effects of different protocols on test outcomes.

Int J Pediatr Otorhinolaryngol

McGill Auditory Sciences Laboratory, McGill University, Montréal, QC, Canada; Department of Otolaryngology - Head and Neck Surgery, McGill University, Montréal, QC, Canada. Electronic address:

Published: May 2014

Background And Objectives: Otoacoustic emission (OAE) tests are currently used to screen newborns for congenital hearing loss in many Universal Newborn Hearing Screening programs. However, there are concerns about high referral and false-positive rates. Various protocols have been used to address this problem. The main objective of this review is to determine the effects of different screening protocols on the referral rates and positive predictive values (PPV) of the OAE newborn screening test.

Methods: Eligible studies published in English from January 1990 until August 2012 were identified through searches of MEDLINE, Medline In-Process, Embase, PubMed (NCBI), ISI Web of Science, and the Cochrane Central Register of clinical controlled trials. Two reviewers independently screened the data sources, using pre-defined inclusion criteria to generate a list of eligible articles. Data extracted included the number of newborns screened, age at screening, OAE pass criteria, frequencies screened, number of retests, referral rates, and the number of newborns identified with permanent congenital hearing loss.

Results: Ten articles met the inclusion criteria, with a total of 119,714 newborn participants. The pooled referral rate was 5.5%. Individual referral rates ranged from 1.3% to 39%; the PPV from 2 to 40%. Increasing the age at initial screening and performing retests reduced the referral rate. Likewise, screenings involving higher frequencies had lower referral rates.

Conclusion: Delaying newborn hearing screening improves test results but may not be practical in all contexts. The use of higher frequencies and more sophisticated OAE devices may be useful approaches to ensure better performance of the OAE test in newborn hearing screening.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ijporl.2014.01.021DOI Listing

Publication Analysis

Top Keywords

newborn hearing
16
hearing screening
16
referral rates
12
screening
8
congenital hearing
8
inclusion criteria
8
number newborns
8
referral rate
8
higher frequencies
8
referral
7

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!