Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: Selectively flexible rings, Colvin-Galloway (CG) Future and Carpentier-Edwards (CE) Physio II, are used for annuloplasty during mitral valve repair to facilitate dynamic annular motion while preventing annular dilation. In this study, we assessed the extent and nature of the flexibility of these rings in vivo, which has not been objectively demonstrated.
Methods: Three-dimensional transesophageal echocardiography was used intraoperatively to acquire data regarding dynamic motion of mitral annuli and annuloplasty rings in 33 patients undergoing mitral repair (15 CG Future and 18 CE Physio II) and in 15 control patients. Data were analyzed to assess the dynamic changes in annular geometry after implantation of selectively flexible rings.
Results: After annuloplasty, there was an immediate and significant decrease in annular displacement (p < 0.001) and annular displacement velocity (p < 0.01). Dynamic change in multiple variables including anteroposterior diameter (p < 0.001) and annular area (p < 0.001) was also significantly depressed. In comparison with normal mitral valves, partially flexible rings allowed limited dynamic motion: percentage changes in anteroposterior diameter (p < 0.001), anterolateral posteromedial diameter (p < 0.001), and total circumference (p < 0.001) were significantly lower. Compared with each other, the two rings resulted in similar changes in anterior annulus length (p = 0.93), posterior annular length (p = 0.82), and annular area (p = 0.31).
Conclusions: Mitral annular dynamics were uniformly depressed after implantation of these rings. Selective flexibility could not be demonstrated in vivo using echocardiographic data.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6563339 | PMC |
http://dx.doi.org/10.1016/j.athoracsur.2014.01.012 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!