A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

In-vivo analysis of selectively flexible mitral annuloplasty rings using three-dimensional echocardiography. | LitMetric

In-vivo analysis of selectively flexible mitral annuloplasty rings using three-dimensional echocardiography.

Ann Thorac Surg

Department of Anesthesia, Critical Care and Pain Medicine, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts.

Published: June 2014

Background: Selectively flexible rings, Colvin-Galloway (CG) Future and Carpentier-Edwards (CE) Physio II, are used for annuloplasty during mitral valve repair to facilitate dynamic annular motion while preventing annular dilation. In this study, we assessed the extent and nature of the flexibility of these rings in vivo, which has not been objectively demonstrated.

Methods: Three-dimensional transesophageal echocardiography was used intraoperatively to acquire data regarding dynamic motion of mitral annuli and annuloplasty rings in 33 patients undergoing mitral repair (15 CG Future and 18 CE Physio II) and in 15 control patients. Data were analyzed to assess the dynamic changes in annular geometry after implantation of selectively flexible rings.

Results: After annuloplasty, there was an immediate and significant decrease in annular displacement (p < 0.001) and annular displacement velocity (p < 0.01). Dynamic change in multiple variables including anteroposterior diameter (p < 0.001) and annular area (p < 0.001) was also significantly depressed. In comparison with normal mitral valves, partially flexible rings allowed limited dynamic motion: percentage changes in anteroposterior diameter (p < 0.001), anterolateral posteromedial diameter (p < 0.001), and total circumference (p < 0.001) were significantly lower. Compared with each other, the two rings resulted in similar changes in anterior annulus length (p = 0.93), posterior annular length (p = 0.82), and annular area (p = 0.31).

Conclusions: Mitral annular dynamics were uniformly depressed after implantation of these rings. Selective flexibility could not be demonstrated in vivo using echocardiographic data.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6563339PMC
http://dx.doi.org/10.1016/j.athoracsur.2014.01.012DOI Listing

Publication Analysis

Top Keywords

selectively flexible
12
diameter 0001
12
annular
9
annuloplasty rings
8
flexible rings
8
dynamic motion
8
annular displacement
8
0001 annular
8
anteroposterior diameter
8
annular area
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!