A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A fully implanted intramuscular bipolar myoelectric signal recording electrode. | LitMetric

A fully implanted intramuscular bipolar myoelectric signal recording electrode.

Neuromodulation

Case Western Reserve University, Cleveland, OH, USA; Cleveland FES Center, Cleveland, OH, USA.

Published: December 2014

Objectives: The objective of this study is to develop a fully implanted, intramuscular, bipolar, myoelectric signal (IM-MES) recording electrode for functional electrical stimulation (FES), prosthetic myoelectric control, and other permanently implantable systems.

Materials And Methods: An existing fully implanted intramuscular stimulating electrode was modified at each end to allow bipolar recording. The design change also required a modification of the implantation method. Mechanical and in vivo testing was performed on the novel components of the electrode. The first clinical application also is described.

Results: The electrode design modifications did not create any areas of excess mechanical strain on the wires at the distal end where the leads were wound into electrode surfaces. In vivo testing showed that the IM-MES electrode recorded myoelectric signals that were equivalent to an existing epimysial MES electrode. The modified implantation method was simple to implement. The IM-MES electrode was used in an upper extremity FES system in an individual with a spinal cord injury and provided signals that were suitable for a command signal.

Conclusions: A fully implanted, bipolar intramuscular recording electrode (IM-MES) was developed. Implantation of the IM-MES is straightforward, and almost any muscle can be targeted. Testing has been performed to demonstrate the suitability of the IM-MES electrode for clinical use. Initial clinical applications were successful.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4160438PMC
http://dx.doi.org/10.1111/ner.12165DOI Listing

Publication Analysis

Top Keywords

fully implanted
16
implanted intramuscular
12
recording electrode
12
im-mes electrode
12
electrode
11
intramuscular bipolar
8
bipolar myoelectric
8
myoelectric signal
8
electrode modified
8
implantation method
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!