Background: Nonfluoroscopic mapping systems have demonstrated significant reduction of radiation exposure in radiofrequency (RF) catheter ablation procedures. However, their use as only imaging guide is still limited.

Objective: To evaluate the usefulness of a completely nonfluoroscopic approach to catheter ablation of supraventricular arrhythmias using the Ensite-NavX™ electroanatomical navigation system.

Methods: During 6 years, all consecutive patients referred for RF catheter ablation of regular supraventricular tachycardia (SVT) were admitted for a "zero-fluoroscopy" approach and studied prospectively. The only exclusion criterion was the need to perform a transseptal puncture.

Results: A total of 340 procedures were performed on 328 patients (179 men, age 55.7 ± 18.6 years). One hundred fifty-three patients had typical atrial flutter (AFL), 146 had AV nodal reentrant tachycardia (AVNRT), 35 had AV reciprocating tachycardia (AVRT), 4 patients had incisional atrial flutter (IAF), and 2 had focal atrial tachycardia (AT). Procedural success was achieved in 337 of the cases (99.1%). In 322 (94.7%), the procedure was completed without any fluoroscopy use. Mean procedure time was 110.5 ± 51.8 minutes. Mean RF application time was 9.8 ± 12.8 minutes and the number of RF lesions was 16.43 ± 15.8. Only 1 major complication related to vascular access was recorded. During follow-up, there were 12 recurrences (3.5%) (8 patients from the AVNRT group, 4 patients from the AP group).

Conclusion: RF catheter ablation of SVT with an approach completely guided by the NavX system and without use of fluoroscopy is feasible, safe, and effective.

Download full-text PDF

Source
http://dx.doi.org/10.1111/jce.12385DOI Listing

Publication Analysis

Top Keywords

catheter ablation
20
ablation procedures
8
atrial flutter
8
patients
6
catheter
5
ablation
5
exclusion fluoroscopy
4
fluoroscopy catheter
4
procedures years
4
years experience
4

Similar Publications

Background: Electrographic flow (EGF) mapping allows for the visualization of global atrial wavefront propagations. One mechanism of initiation and maintenance of atrial fibrillation (AF) is stimulation from EGF-identified focal sources that serve as driver sites of fibrillatory conduction. Electrographic flow consistency (EGFC) further quantifies the concordance of observed wavefront patterns, indicating that a healthier substrate shows more organized wavefront propagation and higher EGFC.

View Article and Find Full Text PDF

Background: Recent data showed an association between malnutrition and increased all-cause mortality and thromboembolic risk in patients with atrial fibrillation (AF). However, the impact of malnutrition on the clinical outcomes for patients undergoing catheter ablation for AF is still debated. Our study aimed to examine this relationship using all existing available data.

View Article and Find Full Text PDF

A 17-year-old patient presented with frequent palpitations, where the tachycardia was not sustained and could not be induced, making it impossible to pinpoint the earliest activation site using the activation map. However, by utilizing a dual-chamber electrogram-based pace mapping technique, we successfully identified the origin and achieved effective treatment.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!