Little empirical evidence exists on the comparability of heart rate variability (HRV) quantification methods commonly used in infants. The aim was to compare three methods of HRV estimation: (1) fast Fourier transform (FFT), (2) autoregressive (AR), and (3) the Porges methods. HRV was estimated in 63 healthy 5-month-old infants. HRV parameters were strongly correlated across methods (.92-.99) but yielded significantly different mean HRV estimates (Porges method > FFT > AR). There was no systematic bias over the whole range of values between the two spectral approaches, while differences between the Porges method and the spectral estimates were systematically greater for larger values. Additional comparative studies are needed to explore the between-method agreement across a range of physiological conditions.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/psyp.12194 | DOI Listing |
Sensors (Basel)
January 2025
College of Information Science and Engineering, Hohai University, Changzhou 213200, China.
Fast Fourier Transform-based Space-Time Image Velocimetry (FFT-STIV) has gained considerable attention due to its accuracy and efficiency. However, issues such as false detection of MOT and blind areas lead to significant errors in complex environments. This paper analyzes the causes of FFT-STIV gross errors and then proposes a method for validity identification and rectification of FFT-STIV results.
View Article and Find Full Text PDFSci Rep
January 2025
School of Information, Yunnan University, Kunming, 650504, China.
Detecting bolt defects on transmission lines is crucial for ensuring the safe operation of the electrical power system. However, existing methods for detecting bolt defects on transmission lines require higher detection accuracy and smaller model sizes. To address these challenges, this paper proposes a real-time bolt defect detection model based on YOLOv7, named YOLOv7-CWFD.
View Article and Find Full Text PDFInt J Biol Macromol
January 2025
Department of Chemical Engineering, Dr. B. R. Ambedkar National Institute of Technology, Jalandhar 144008, Punjab, India.
J Clin Neurophysiol
December 2024
Human Brain Mapping Program, University of Pittsburgh Medical Centre, Pittsburgh, Pennsylvania, U.S.A.; and.
Objectives: Our study aimed to compare signal characteristics of subdural electrodes (SDE) and depth stereo EEG placed within a 5-mm vicinity in patients with drug-resistant epilepsy. We report how electrode design and placement collectively affect signal content from a shared source between these electrode types.
Methods: In subjects undergoing invasive intracranial EEG evaluation at a surgical epilepsy center from 2012 to 2018, stereo EEG and SDE electrode contacts placed within a 5-mm vicinity were identified.
J Magn Reson Imaging
January 2025
Department of Radiology, Shandong Provincial Hospital Affiliated to Shandong First Medical University, Jinan, China.
Background: Bladder injury during cesarean delivery (CD) in pregnant women with severe placenta accreta spectrum (PAS) disorders mostly occurs in the dissection of vesico-uterine space. Placental MRI may help to assess the risk of bladder injury preoperatively.
Purpose: To identify the high-risk MRI signs of bladder injury during CD in women with severe PAS.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!