The aim of the study was to evaluate the diagnostic accuracy of ct-bypass angiography in the evaluation of significant stenosis and occlusion of grafts, recipient and nongrafted vessels in patients after coronary bypass surgery in the late postoperative period. Ct-bypass angiography was performed on 64-slice ct scanner with a slice thickness of 0.5 mm and a gantry rotation time of 0.4 s. All results were compared with quantitative invasive coronary angiography. 43 patients with 113 grafts were included in the study. Sensitivity, specificity, positive and negative predictive value, and diagnostic accuracy for the evaluation of significant stenosis were 94%, 95%, 88%, 98%, 95%, respectively. Diagnostic accuracy for the evaluation of significant stenosis in the recipient and nongrafted vessels were 91% and 90%, respectively. The diagnostic accuracy for the evaluation graft occlusion, recipient and nongrafted vessels was 100%, 100% and 98%, respectively. Ct-bypass angiography allows accurate non-invasive assessment of significant stenosis and occlusion of coronary bypass grafts and native coronary arteries in patients after coronary bypass surgery in the late postoperative period.
Download full-text PDF |
Source |
---|
The aim of the study was to evaluate the diagnostic accuracy of ct-bypass angiography in the evaluation of significant stenosis and occlusion of grafts, recipient and nongrafted vessels in patients after coronary bypass surgery in the late postoperative period. Ct-bypass angiography was performed on 64-slice ct scanner with a slice thickness of 0.5 mm and a gantry rotation time of 0.
View Article and Find Full Text PDFInvest Radiol
April 2008
Institut für Radiologie und Nuklearmedizin, Deutsches Herzzentrum München, München, München, Germany.
Objectives: The objectives of this prospective investigation in patients after bypass graft surgery were (1) to estimate radiation dose for routine bypass graft computed tomography (CT) angiography, (2) to study the impact of anatomically adapted and ECG-controlled tube current modulation on radiation dose estimates, and (3) effects on qualitative and quantitative image quality parameters.
Methods: Radiation dose was estimated for 194 consecutive patients undergoing 64-slice CT angiography (Somatom Sensation 64 Cardiac, Siemens Medical Solutions). The impact of anatomically adapted tube current modulation was studied in 2 consecutive patients groups.