This study aimed to define accelerations measured at the waist and lower extremities over a range of gait velocities to provide reference data for choosing the appropriate accelerometer for field-based human activity monitoring studies. Accelerations were measured with a custom activity monitor (± 16g) at the waist, thighs, and ankles in 11 participants over a range of gait velocities from slow walking to running speeds. The cumulative frequencies and peak accelerations were determined. Cumulative acceleration amplitudes for the waist, thighs, and ankles during gait velocities up to 4.8 m/s were within the standard commercial g-range (± 6g) in 99.8%, 99.0%, and 96.5% of the data, respectively. Conversely, peak acceleration amplitudes exceeding the limits of many commercially available activity monitors were observed at the waist, thighs, and ankles, with the highest peaks at the ankles, as expected. At the thighs, and more so at the ankles, nearly 50% of the peak accelerations would not be detected when the gait velocity exceeds a walking velocity. Activity monitor choice is application specific, and investigators should be aware that when measuring high-intensity gait velocity activities with commercial units that impose a ceiling at ± 6g, peak accelerations may not be measured.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4180224PMC
http://dx.doi.org/10.1123/jab.2013-0264DOI Listing

Publication Analysis

Top Keywords

gait velocities
16
thighs ankles
16
range gait
12
activity monitor
12
accelerations measured
12
waist thighs
12
peak accelerations
12
waist lower
8
lower extremities
8
extremities range
8

Similar Publications

Objective: This multicenter, randomized, double-blind, placebo-controlled, crossover trial aimed to evaluate whether prolonged noisy galvanic vestibular stimulation improves body balance in patients with vestibulopathy.

Materials And Methods: This trial was registered in the Japan Pharmaceutical Information Center Clinical Trials Information registry (jRCT1080224083). Subjects were 20- to 85-year-old patients who had been unsteady for more than one year and whose symptoms had persisted despite more than six months of rehabilitation.

View Article and Find Full Text PDF

With advancements in bipedal locomotion for humanoid robots, a critical challenge lies in generating gaits that are bounded to ensure stable operation in complex environments. Traditional Model Predictive Control (MPC) methods based on Linear Inverted Pendulum (LIP) or Cart-Table (C-T) methods are straightforward and linear but inadequate for robots with flexible joints and linkages. To overcome this limitation, we propose a Flexible MPC (FMPC) framework that incorporates joint dynamics modeling and emphasizes bounded gait control to enable humanoid robots to achieve stable motion in various conditions.

View Article and Find Full Text PDF

Rehabilitation of gait function in post-stroke hemiplegic patients is critical for improving mobility and quality of life, requiring a comprehensive understanding of individual gait patterns. Previous studies on gait analysis using unsupervised clustering often involve manual feature extraction, which introduces limitations such as low accuracy, low consistency, and potential bias due to human intervention. This cross-sectional study aimed to identify and cluster gait patterns using an end-to-end deep learning approach that autonomously extracts features from joint angle trajectories for a gait cycle, minimizing human intervention.

View Article and Find Full Text PDF

The Role of AMPS in Parkinson's Disease Management: Scoping Review and Meta-Analysis.

Bioengineering (Basel)

December 2024

Pediatric Physical Medicine and Rehabilitation Unit, IRCCS Institute of Neurological Sciences, 40139 Bologna, Italy.

Automated Mechanical Peripheral Stimulation (AMPS) is emerging as a potential therapeutic tool for managing motor and non-motor symptoms in individuals with Parkinson's disease (PD), particularly in terms of improving gait, balance, and autonomic regulation. This scoping review aims to synthesize current evidence on AMPS's effectiveness for these outcomes. A review was conducted on MEDLINE, Cochrane Central, Scopus, PEDro, and Web of Science.

View Article and Find Full Text PDF

Introduction: The purpose of this study was to investigate the relationships between a Power Leg Press test (PLP) with walking capacity and self-reported performance and participation in individuals with Cerebral Palsy (CP), and to compare the strength of the associations between two power tests (PLP and isokinetic (IsoK)) with walking capacity.

Methods: Ambulatory individuals with CP (n = 33; age 17.89 ± 7.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!