Physiological sensitivity of respiratory-dependent cardiac pacing: four-year follow-up.

Pacing Clin Electrophysiol

Divisione di Cardiologia, Ospedale Maggiore della Carità, Novara, Italy.

Published: September 1988

Clinical and physiological data on long-term follow-up of 143 patients with respiratory-dependent pacemakers (RDP3) are reported; 121 patients received ventricular (VVI-RD) and 22 patients atrial (AAI-RD) respiratory-dependent stimulation. Functional evaluation was based on the exercise testing (130 pts) with oxygen uptake VO2, ventilation, ECG and arterial pressure monitoring and the dynamic Holter electrocardiogram (95 pts). In each patient, the stimulation rate curve selected was that which produced the best work tolerance and moved the anaerobic threshold to the right. Respiratory levels were assessed by telemetry verifying proper sensing of tidal volume variations and absence of interference and artefacts. In patients with VVIR or AAIR stimulation, exercise tolerance, oxygen uptake and anaerobic threshold increased significantly in comparison with VVI or AAI pacing respectively. The physiological sensitivity of the stimulation system (i.e., a linear relationship of the pacing rate with metabolic requirements) was excellent (up to exhaustion) in 70%, very good (up to anaerobic threshold) in 20% and erratic (no relationship between pacing rate and VE/VO2) in 10% of patients. In dynamic electrocardiographic monitoring, the automatic pacing rate was always predominant during the night and during rest periods; the pacing rate increased properly with daily activity; myopotential inhibition (none longer than 3,500 ms) was observed in 38 patients, but without subjective complaints. The incidence of the RDP3 malfunction was less than 8%; it may have stemmed from the pacing system itself, or from other clinical conditions. Oversensing of impedance system pulses has not been recorded in the last 3 years. Partial respiration undersensing results from incorrect accessory lead position, pulmonary emphysema, marked obesity or other causes. Respiratory sensing becomes erratic at the anaerobic threshold point in such patients, but functions well at submaximum exercise levels. In patients with left ventricular failure, exercise tolerance was improved by setting a lower ratio between the pacing rate and respiration, which prevented the occurrence of excessive pacing rates.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1540-8159.1988.tb03987.xDOI Listing

Publication Analysis

Top Keywords

pacing rate
20
anaerobic threshold
16
pacing
9
physiological sensitivity
8
patients
8
oxygen uptake
8
exercise tolerance
8
relationship pacing
8
rate
6
sensitivity respiratory-dependent
4

Similar Publications

Left Atrial Appendage Occlusion in Patients With Atrial Fibrillation and Hemodialysis: An International, Multicentric Registry.

JACC Clin Electrophysiol

January 2025

Cardioangiologisches Centrum Bethanien, Agaplesion Markus-Krankenhaus, Frankfurt am Main, Germany.

Background: The net benefit of oral anticoagulation in patients with end-stage renal disease on hemodialysis (HD) is uncertain. In recent years, left atrial appendage closure (LAAC) has emerged as an alternative to oral anticoagulation; however, there is scant evidence of LAAC in patients on HD.

Objectives: This study aimed to assess the feasibility and safety of LAAC in patients on HD.

View Article and Find Full Text PDF

Purpose: To investigate technical regulation mechanisms of long-distance swimmers that differentiate optimal pacing strategies and the underlying kinematic parameters.

Methods: Twenty-one national and international swimmers were equipped with a sacrum-worn inertial measurement unit performed during 5000-m indoor French championships. Percentage of critical swimming speed (CSS), stroke rate, stroke length, jerk cost, stroke index, and mechanical proficiency score were computed by lap.

View Article and Find Full Text PDF

Objective: The Vizigo sheath, a novel visualizable steerable sheath, has been utilized effectively in the clinical management of atrial fibrillation. However, its application in the ablation of typical atrial flutter (AFL) remains unexplored. This study aims to evaluate and compare the efficacy and safety of the Vizigo sheath against a conventional fixed sheath during catheter ablation for typical AFL.

View Article and Find Full Text PDF

This case details the successful implantation of a leadless pacemaker following the extraction of transvenous leads in a 72-year-old female patient with a complex cardiovascular history. The patient had undergone a series of cardiac interventions, including a recent percutaneous tricuspid valve repair with a metal clip implant due to severe regurgitation. After presenting with an infection at the pacemaker site, methicillin-resistant Staphylococcus hominis was identified, necessitating the removal of the entire pacing system.

View Article and Find Full Text PDF

Alterations in energy metabolism may drive fatigue in older age, but prior research primarily focused on skeletal muscle energetics without assessing other systems, and utilized self-reported measures of fatigue. We tested the association between energy metabolism in the brain and an objective measure of fatigability in the Study of Muscle, Mobility and Aging (N=119, age 76.8±4.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!