Pathogens such as viruses and bacteria use their envelope proteins and their adhesin lectins to recognize the glycan residues presented on the cell surface of the target tissues. This principle of recognition is used in a new electrochemical displacement sensor for the protein concanavalin A (ConA). A gold electrode was first modified with a self-assembled monolayer of a thiolated mannose/OEG conjugate and a ferrocene boroxol derivative was pre-assembled as reporter molecule onto the mannose surface. The novel tracer molecule based on a 2-hydroxymethyl phenyl boronic acid derivative binds even at neutral pH to the saccharides which could expand the application towards biological samples (i.e., urine and feces). Upon the binding of ConA, the tracer was displaced and washed away from the sensor surface leading to a decrease in the electrochemical signal. Using square wave voltammetry (SWV), the concentration of ConA in the sample solution could be determined in the dynamic concentration range established from 38nmolL(-1) to 5.76µmolL(-1) with a reproducible detection limit of 1µgmL(-1) (38nmolL(-1)) based on the signal-to-noise ratio (S/N=3) with fast response of 15min. The new reporter molecule showed a reduced non-specific displacement by BSA and ribonuclease A. The sensor was also successfully transferred to the first proof of principle for the detection of Escherichia coli exhibiting a detection limit of approximately 6×10(2)cells/mL. Specificity of the displacement by target protein ConA and E. coli was demonstrated since the control proteins (i.e., BSA and RNaseA) and the control E. coli strain, which lack of type 1 fimbriae, were ineffective.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.bios.2014.02.028DOI Listing

Publication Analysis

Top Keywords

electrochemical displacement
8
displacement sensor
8
boronic acid
8
reporter molecule
8
detection limit
8
sensor
4
sensor based
4
based ferrocene
4
ferrocene boronic
4
acid tracer
4

Similar Publications

The diversity and heterogeneity of biomarkers has made the development of general methods for single-step quantification of analytes difficult. For individual biomarkers, electrochemical methods that detect a conformational change in an affinity binder upon analyte binding have shown promise. However, because the conformational change must operate within a nanometer-scale working distance, an entirely new sensor, with a unique conformational change, must be developed for each analyte.

View Article and Find Full Text PDF
Article Synopsis
  • Using alternating currents (AC) can effectively prevent the formation of mineral crystals on surfaces in contact with super-saturated fluids, such as heat exchangers and pipes.
  • The study demonstrates that periodic charging and discharging of the electrical double layer (EDL) on titanium sheets in super-saturated CaCO solutions inhibits both crystal nucleation and growth due to enhanced ion migration.
  • Operating at 4 V and frequencies between 0.1-10 Hz results in over 96% reduction in turbidity and over 92% reduction in calcium carbonate coverage, showcasing a promising method for controlling mineral scaling in various industrial applications.
View Article and Find Full Text PDF

Epidemic infections and spreading antibiotic resistance require diagnostic tests that can be rapidly adopted. To reduce the usually time-consuming adaptation of molecular diagnostic tests to changing targets, we propose the novel approach of a repurposable sensing electrode functionalization with a universal, target-independent oligonucleotide probe. In the liquid phase covering the electrode, the target sequence is amplified by MD LAMP (mediator-displacement loop-mediated isothermal amplification) releasing a generic methylene blue-labeled mediator, which specifically hybridizes to the solid-phase probe.

View Article and Find Full Text PDF

Highly sensitive and accurate detection of disease biomarkers is of great importance for diagnosis, staging, and treatment of certain diseases. Herein, we report a novel electrochemical method for the quantification of miRNA biomarkers with DNA tetrahedrons as the signal reporters. Upon the initiation of DNA hairpin opening by miRNA at the electrode interface, the hidden click reaction group is exposed for the bioconjugation with a tetrahedral DNA nanostructure, which carries multiple electrochemical species.

View Article and Find Full Text PDF

A dual mode biosensor based on self-enhanced polyfluorene nanomaterial for fluorescence and electrochemiluminescence detection of Tau protein.

Biosens Bioelectron

March 2025

Key Laboratory of Luminescence Analysis and Molecular Sensing (Southwest University), Ministry of Education, College of Chemistry and Chemical Engineering, Southwest University, Chongqing, 400715, PR China. Electronic address:

Dual mode detection can overcome the poor anti-interference ability of single-mode detection, and greatly improve the detection accuracy. Fluorescence/electrochemiluminescence (FL/ECL) dual mode detection combines the advantages of FL and ECL, and has a promising application in bioanalysis. Common FL/ECL dual mode detection used different signal probes.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!