The Major connector is the major component of the cast partial denture to which all other parts are directly or indirectly attached. It also provides cross arch stability to help resist displacement by functional stresses. The major connector should be rigid. A flexible major connector causes an unequal distribution of forces with changes in their intensity and may cause damage to the supporting structures. Thus rigidity is of paramount to resist flexing and torquing forces. The commonly used major connectors for the maxillary arch are Anteroposterior strap, palatal strap and complete palatal plate. Application of load on the prosthesis will result in deflection. The magnitude and direction of the deflection that the prosthesis undergoes depends on the rigidity of the major connector. (1) To determine the deflection seen in maxillary removable partial denture frameworks under simulated occlusal load. (2) To compare the rigidity and deflection characteristics of different maxillary major connectors used in maxillary Kennedy's class I, class II, class III and class IV situations. A CT scan of human edentulous maxilla was taken and each section from the incisive foramen to the hamular notch was projected on the graph paper and three dimensional volumes were created from the connected successive profiles to define the final solid geometry of bone. Six framework models with different Maxillary major connectors such as Anteroposterior straps and complete palatal plate for Kennedy's class I, class II, class III and class IV situations were created. Three Dimensional Finite Element Models corresponding to the geometric model were created using ANSYS 9.0 version. The model was assigned the material properties. A vertical biting force of 20 N was applied. The results showed maximum displacements were observed at the posterior edge of the saddle for all the frameworks. Anteroposterior palatal strap in class III and class IV situation showed the least deflection when compared to class I and class II (distal extension situation) Anteroposterior palatal strap is more rigid connector than the full palatal plate, single palatal strap, and U-shaped palatal strap and can be used in all situations.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3935043PMC
http://dx.doi.org/10.1007/s13191-012-0237-3DOI Listing

Publication Analysis

Top Keywords

palatal strap
20
class class
20
major connectors
16
major connector
16
maxillary major
12
palatal plate
12
class
12
class iii
12
iii class
12
major
9

Similar Publications

Backgrounds: Nasoalveolar molding (NAM) application is among presurgical management (PSM) techniques used for infants with cleft lip and palate (CLP). It helps to approximate the palatal cleft and to reshape the nasoalveolar complex prior to primary lip repair. This study aimed to explore types of PSM and the dental speciality provision for infants with CLP in Baghdad.

View Article and Find Full Text PDF

Objectives: The purpose of this study was to measure the effectiveness of the cervical headgear for distalizing first permanent maxillary molars in relation to hours of use.

Methods: This was a one-centre, prospective, clinical study conducted at the Department of Orthodontics, School of Dentistry, National and Kapodistrian University of Athens, Athens, Greece. Participants (N = 26; 17 females, 9 males) were patients with no history of orthodontic treatment, no syndromes or clefts, and Angle's Class II malocclusion, where the treatment plan included a cervical headgear.

View Article and Find Full Text PDF

Cleft palate is the absence of the vault of the mouth resulting in communication between the nose and the mouth. The current frequency of cleft is 0.3% among black people.

View Article and Find Full Text PDF

Objectives: To measure and compare the accuracy of 3D-printed materials used for RPD production to improve workflow and eliminate errors in manufacturing.

Methods: A partially edentulous maxilla (Kennedy Class III, modification 1) was prepared and designed with proximal plates, rest seats and clasps in one first premolar, one canine and two second molars. A total of 540 3D printed RPD frameworks were 3D printed with three different types of resin (DentaCAST (Asiga, Australia), SuperCAST (Asiga, Australia) and NextDent (3D Systems, Netherlands)).

View Article and Find Full Text PDF

Objective: To compare the short-term treatment effects between two types of facemasks in skeletal Class III patients.

Materials And Methods: This retrospective study included 40 skeletal Class III subjects (mean age: 7.7 years) who had been treated with protraction facemasks with forehead straps (PFFS) or Petit type facemasks (PTF).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!