Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Unlabelled: The activPAL is an accelerometer-based monitor worn on the thigh that classifies daily activities into three categories (sitting/lying down, standing, and stepping). The monitor discriminates between sitting/lying and the upright position by detecting the inclination of the thigh. It detects stepping from the acceleration versus time wave form. However, a current limitation of the activPAL is that it does not discriminate between sitting and lying down.
Purpose: This study aimed to determine whether placing a second activPAL monitor on the torso would allow the detection of seated versus lying postures.
Methods: Fifteen healthy adults (18-55 yr of age) wore an activPAL on the right thigh and another activPAL over the right rib cage. Both monitors were synchronized and initialized to record data in 15-s epochs. Participants performed a semistructured routine of activities for 3 min each. Activities included lying down (while supine, prone, and on the side), sitting, standing, sweeping, treadmill walking at 3 mph, and treadmill running at 6 mph. The spatial orientation of the thigh and chest monitors was used to determine body posture, and the activPAL on the thigh was used to detect ambulation.
Results: The use of two activPAL devices enabled four behaviors to be accurately classified. The percentages of observations that were classified accurately were as follows: lying down (100%), sitting (100%), standing/light activity in the upright position (90.8%), and stepping (100%).
Conclusions: The current method allows researchers to obtain more detailed information on postural allocation compared with that in the use of a single activPAL on the thigh.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1249/MSS.0000000000000326 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!