A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Reproducibility of non-invasive a1 adenosine receptor quantification in the rat brain using [(18)F]CPFPX and positron emission tomography. | LitMetric

Purpose: The A1AR antagonist 8-cyclopentyl-3-(3-fluoropropyl)-1-propylxanthine ([(18)F]CPFPX) has recently been shown to be a suitable radiotracer for quantitative in vivo imaging of the A1 adenosine receptor (A1AR) in rats. The present study evaluates the reproducibility of non-invasive longitudinal A1AR studies with [(18)F]CPFPX and a dedicated small animal positron emission tomography (PET) scanner.

Procedures: Twelve male Sprague Dawley rats underwent four repeated dynamic PET scans with a bolus injection of [(18)F]CPFPX. A1AR availability was determined by different non-invasive approaches including simplified and multilinear reference tissue (olfactory bulb)-based models and graphical methods. The outcome parameter binding potential (BP) was evaluated in terms of variability and reproducibility.

Results: Repeated estimations of [(18)F]CPFPX BP ND gave reliable results with acceptable variability (mean 12 %) and reproducibility (intraclass correlation coefficients raging from 0.57 to 0.68) in cortical and subcortical regions of the rat brain. With regard to kinetic models, test-retest stability of the simplified reference-tissue model (SRTM) was superior to multilinear and graphical approaches.

Conclusions: Non-invasive quantification of A1AR density in the rat brain is reproducible and reliable with [(18)F]CPFPX PET and allows longitudinal designs of in vivo imaging studies in rodents.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s11307-014-0729-0DOI Listing

Publication Analysis

Top Keywords

rat brain
12
reproducibility non-invasive
8
adenosine receptor
8
positron emission
8
emission tomography
8
vivo imaging
8
[18f]cpfpx
6
a1ar
5
non-invasive adenosine
4
receptor quantification
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!