Rationale And Objectives: Our objective is to determine whether expected utility (EU) and the area under the receiver operator characteristic (AUC) are consistent with one another as endpoints of observer performance studies in mammography. These two measures characterize receiver operator characteristic performance somewhat differently. We compare these two study endpoints at the level of individual reader effects, statistical inference, and components of variance across readers and cases.
Materials And Methods: We reanalyze three previously published laboratory observer performance studies that investigate various x-ray breast imaging modalities using EU and AUC. The EU measure is based on recent estimates of relative utility for screening mammography.
Results: The AUC and EU measures are correlated across readers for individual modalities (r = 0.93) and differences in modalities (r = 0.94 to 0.98). Statistical inference for modality effects based on multi-reader multi-case analysis is very similar, with significant results (P < .05) in exactly the same conditions. Power analyses show mixed results across studies, with a small increase in power on average for EU that corresponds to approximately a 7% reduction in the number of readers. Despite a large number of crossing receiver operator characteristic curves (59% of readers), modality effects only rarely have opposite signs for EU and AUC (6%).
Conclusions: We do not find any evidence of systematic differences between EU and AUC in screening mammography observer studies. Thus, when utility approaches are viable (i.e., an appropriate value of relative utility exists), practical effects such as statistical efficiency may be used to choose study endpoints.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3952000 | PMC |
http://dx.doi.org/10.1016/j.acra.2013.12.011 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!