Design of the plasma chamber and beam extraction system for SC ECRIS of RAON accelerator.

Rev Sci Instrum

The Rair Isotope Science Project, Institute for Basic Science, Daejeon 305-811, South Korea.

Published: February 2014

The RAON accelerator is the heavy ion accelerator being built in Korea. It contains a 3rd generation SC ECRIS which uses 28 GHz/18 GHz microwave power to extract 12 puA uranium ion beams. A plasma chamber for that ECRIS is made of aluminum machined from bulk Al. That chamber contains cooling channels to remove dumped power and another access port for microwave introduction and plasma diagnostics. Beam extraction electrodes were designed considering the engineering issues and preliminary beam extraction analysis was done. That plasma chamber will be assembled with a cryostat, and beam extraction experiment will be done.

Download full-text PDF

Source
http://dx.doi.org/10.1063/1.4825385DOI Listing

Publication Analysis

Top Keywords

beam extraction
16
plasma chamber
12
raon accelerator
8
design plasma
4
chamber
4
beam
4
chamber beam
4
extraction
4
extraction system
4
system ecris
4

Similar Publications

Purpose: The use of cone-beam computed tomographies (CBCT) in orthodontics and pediatric dentistry is constantly increasing. The aim of this systematic review was to critically appraise and summarize evidence from clinical studies on the prevalence of incidental findings from CBCTs of children and adolescents.

Methods: Systematic literature searches without restrictions were undertaken in eight databases from inception up to March 2024 for studies reporting on incidental findings from CBCT images of children and adolescents.

View Article and Find Full Text PDF

Beam-divergence characteristics of single negative ion beamlet have been experimentally investigated with a superimposition of a controlled perturbation of a radio frequency wave (RF) field in a filament-arc discharge negative ion source. Oscillations of a negative-ion beamlet width and axis responding to the RF perturbation were observed, which may be a cause of the larger beam divergence angle of the RF negative ion source for ITER. It is pointed out that the oscillation of the beamlet width depends on the perveance and on an RF frequency such that the oscillation is suppressed at perveance-matched conditions and at low RF frequency.

View Article and Find Full Text PDF

Transmission electron microscopy, especially at cryogenic temperature, is largely used for studying biological macromolecular complexes. A main difficulty of TEM imaging of biological samples is the weak amplitude contrasts due to electron diffusion on light elements that compose biological organisms. Achieving high-resolution reconstructions implies therefore the acquisition of a huge number of TEM micrographs followed by a time-consuming image analysis.

View Article and Find Full Text PDF

This Letter introduces a method for identifying the fast axis and phase retardation of wave plates by means of polarization common-path vortex interferometry. The technique utilizes a composite polarized vortex beam interacting with the wave plate under test. By analyzing the azimuth angle of the dark fringe in the interference pattern, the wave plate's characteristics are accurately extracted.

View Article and Find Full Text PDF

Remember the teeth! Cutaneous manifestation of odontogenic sepsis: A case study.

JPRAS Open

March 2025

Aberdeen Royal Infirmary, NHS Grampian, Aberdeen, United Kingdom.

We present the case of a 21-year-old male with a 3-year history of an isolated 1 × 1 cm purulent lesion on the left cheek, on a background of mild acne. Despite topical treatments, the lump persisted, discharging frank pus regularly. Microbiology swabs and an incisional biopsy were unremarkable.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!