The Institute for Quality and Efficiency in Health Care (IQWiG) developed-in a consultation process with an international expert panel-the efficiency frontier (EF) approach to satisfy a range of legal requirements for economic evaluation in Germany's statutory health insurance system. The EF approach is distinctly different from other health economic approaches. Here, we evaluate established tools for assessing and communicating parameter uncertainty in terms of their applicability to the EF approach. Among these are tools that perform the following: (i) graphically display overall uncertainty within the IQWiG EF (scatter plots, confidence bands, and contour plots) and (ii) communicate the uncertainty around the reimbursable price. We found that, within the EF approach, most established plots were not always easy to interpret. Hence, we propose the use of price reimbursement acceptability curves-a modification of the well-known cost-effectiveness acceptability curves. Furthermore, it emerges that the net monetary benefit allows an intuitive interpretation of parameter uncertainty within the EF approach. This research closes a gap for handling uncertainty in the economic evaluation approach of the IQWiG methods when using the EF. However, the precise consequences of uncertainty when determining prices are yet to be defined.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4489337PMC
http://dx.doi.org/10.1002/hec.3041DOI Listing

Publication Analysis

Top Keywords

parameter uncertainty
12
communicating parameter
8
uncertainty iqwig
8
efficiency frontier
8
economic evaluation
8
uncertainty
7
approach
6
iqwig
4
iqwig efficiency
4
frontier decision-makers
4

Similar Publications

Because of their resilience, Time-of-Flight (ToF) cameras are now essential components in scientific and industrial settings. This paper outlines the essential factors for modeling 3D ToF cameras, with specific emphasis on analyzing the phenomenon known as "wiggling". Through our investigation, we demonstrate that wiggling not only causes systematic errors in distance measurements, but also introduces periodic fluctuations in statistical measurement uncertainty, which compounds the dependence on the signal-to-noise ratio (SNR).

View Article and Find Full Text PDF

During the interaction process of a manipulator executing a grasping task, to ensure no damage to the object, accurate force and position control of the manipulator's end-effector must be concurrently implemented. To address the computationally intensive nature of current hybrid force/position control methods, a variable-parameter impedance control method for manipulators, utilizing a gradient descent method and Radial Basis Function Neural Network (RBFNN), is proposed. This method employs a position-based impedance control structure that integrates iterative learning control principles with a gradient descent method to dynamically adjust impedance parameters.

View Article and Find Full Text PDF

To achieve the actuation of silicone-based foamed composites, a liquid-gas phase transition of the liquid captured in its pores is employed. The uncertainty of key parameters for a single or sequential open-air performance of such soft actuators limits their application. To define the main characteristics of the composites, in this work, two functions of the liquid there were separated: the pore-forming agent (FPA) and working liquid (WL).

View Article and Find Full Text PDF

Despite the significant benefits of aquatic passive sampling (low detection limits and time-weighted average concentrations), the use of passive samplers is impeded by uncertainties, particularly concerning the accuracy of sampling rates. This study employed a systematic evaluation approach based on the combination of meta-analysis and quantitative structure-property relationships (QSPR) models to address these issues. A comprehensive meta-analysis based on extensive data from 298 studies on the Polar Organic Chemical Integrative Sampler (POCIS) identified essential configuration parameters, including the receiving phase (type, mass) and the diffusion-limiting membrane (type, thickness, pore size), as key factors influencing uptake kinetic parameters.

View Article and Find Full Text PDF

Background: Echocardiography is widely used to assess aortic stenosis (AS) but can yield inconsistent results, leading to uncertainty about AS severity and the need for further diagnostics. This retrospective study aimed to evaluate a novel echocardiography-based marker, the signal intensity coefficient (SIC), for its potential in accurately identifying and quantifying calcium in AS, enhancing noninvasive diagnostic methods.

Methods: Between May 2022 and October 2023, 112 cases of AS that were previously considered severe by echocardiography were retrospectively evaluated, as well as a group of 50 cases of mild or moderate AS, both at the Eastern Slovak Institute of Cardiovascular Diseases in Kosice, Slovakia.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!