Purpose: To quantify the impact of diagnostic confidence on radiological diagnosis with a fuzzy logic-based method.

Materials And Methods: Twenty-two oncologic patients with 20 cysts and 30 metastases ≤1 cm in size found at 64-row computed tomography were included. Two readers (R1/R2) expressed diagnoses as a subjective level of confidence P(d) in malignancy within the interval [0,1] rather than on a "crisp" basis (malignant/benign); confidence in benignancy was 1 - p(d). When cross-tabulating data according to the standard of reference, 2 × 2 table cells resulted from the aggregation between p(d)/1 - p(d) and final diagnosis. We then assessed (i) readers diagnostic performance on a fuzzy and crisp basis; (ii) the "divergence" δ(F, C) (%) as a measure of how confidence impacted on crisp diagnosis.

Results: Diagnoses expressed with lower confidence increased fuzzy false positives compared to crisp ones (from 0 to 0.2 for R1; from 1 to 2.4 for R2). Crisp/fuzzy accuracy was 94.0%/93.6% (R1) and 94.0/91.6% (R2). δ(F, C) (%) was larger in the case of the less experienced reader (R2) (up to +7.95% for specificity). According to simulations, δ(F, C) (%) was negative/positive depending on the level of confidence in incorrect diagnoses.

Conclusion: Fuzzy evaluation shows a measurable effect of uncertainty on radiological diagnoses.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3922019PMC
http://dx.doi.org/10.1155/2014/587976DOI Listing

Publication Analysis

Top Keywords

computed tomography
8
fuzzy logic-based
8
impact diagnostic
8
diagnostic confidence
8
confidence radiological
8
radiological diagnosis
8
level confidence
8
confidence
7
fuzzy
5
differentiating small
4

Similar Publications

Background: Intermediate-high risk pulmonary embolism (PE) carries a significant risk of hemodynamic deterioration or death. Treatment should balance efficacy in reducing clot burden with the risk of complications, particularly bleeding. Previous studies on high-dose, short-term thrombolysis with alteplase (rtPA) showed a reduced risk of hemodynamic deterioration but no change in mortality and increased bleeding complications.

View Article and Find Full Text PDF

Objective: To investigate differences in arterial involvement patterns on F-FDG PET-CT between predominant cranial and isolated extracranial phenotypes of giant cell arteritis (GCA).

Methods: A retrospective review of F-FDG PET-CT findings was conducted on 140 patients with confirmed GCA. The patients were divided into two groups: the cranial group, which presented craniofacial ischemic symptoms either at diagnosis or during follow-up, and the isolated extracranial group which never exhibited such manifestations.

View Article and Find Full Text PDF

Early Lung Adenocarcinoma Manifesting as Irregular Subsolid Nodules: Clinical and CT Characteristics.

Acad Radiol

December 2024

Department of Radiology, The First Affiliated Hospital of Chongqing Medical University, No. 1 Youyi Road, Yuzhong District, Chongqing 400016, China (P.-l.Z., T.-y.L., F.-j.L., Q.L.). Electronic address:

Rationale And Objectives: To explore the clinical and computed tomography (CT) characteristics of early-stage lung adenocarcinoma (LADC) that presents with an irregular shape.

Materials And Methods: The CT data of 575 patients with stage IA LADC and 295 with persistent inflammatory lesion (PIL) manifesting as subsolid nodules (SSNs) were analyzed retrospectively. Among these patients, we selected 233 patients with LADC and 140 patients with PIL, who showed irregular SSNs, hereinafter referred to as irregular LADC (I-LADC) and irregular PIL (I-PIL), respectively.

View Article and Find Full Text PDF

Background: Multidose iodinated contrast media (ICM) injectors have shown promise in reducing ICM waste. This study aims to evaluate the impact of patient volume on ICM waste reduction in multidose injectors.

Methods: CT studies performed over one-year period with a multidose injector at our emergency CT unit.

View Article and Find Full Text PDF

A Double-Blind Randomized Crossover Trial Comparing the Esthetic Outcomes Of CAD-CAM Provisional Restorations Fabricated Using CBCT And IOS Acquisition Methods.

J Dent

December 2024

Professor and Clinic director, Clinic of General-, Special Care- and Geriatric Dentistry, Center for Dental Medicine, University of Zurich, Zurich Switzerland. Electronic address:

Objectives: This double-blind randomised crossover trial aimed to compare the aesthetic outcomes of CAD-CAM manufactured provisional restorations created using cone beam computed tomography (CBCT) and intraoral scanners (IOS) acquisition methods.

Methods: Twelve participants (mean-age: 38 ± 5 years) requiring full mouth rehabilitation were included in this crossover trial. Two sets of identical CAD-CAM provisional restorations, differing only in the method of data acquisition (A: CBCT, B: IOS), were fabricated.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!