Background: The measurement of activity energy expenditure (AEE) via accelerometry is the most commonly used objective method for assessing human daily physical activity and has gained increasing importance in the medical, sports and psychological science research in recent years.
Objective: The purpose of this study was to determine which of the following procedures is more accurate to determine the energy cost during the most common everyday life activities; a single regression or an activity based approach. For this we used a device that utilizes single regression models (GT3X, ActiGraph Manufacturing Technology Inc., FL., USA) and a device using activity-dependent calculation models (move II, movisens GmbH, Karlsruhe, Germany).
Material And Methods: Nineteen adults (11 male, 8 female; 30.4±9.0 years) wore the activity monitors attached to the waist and a portable indirect calorimeter (IC) as reference measure for AEE while performing several typical daily activities. The accuracy of the two devices for estimating AEE was assessed as the mean differences between their output and the reference and evaluated using Bland-Altman analysis.
Results: The GT3X overestimated the AEE of walking (GT3X minus reference, 1.26 kcal/min), walking fast (1.72 kcal/min), walking up-/downhill (1.45 kcal/min) and walking upstairs (1.92 kcal/min) and underestimated the AEE of jogging (-1.30 kcal/min) and walking upstairs (-2.46 kcal/min). The errors for move II were smaller than those for GT3X for all activities. The move II overestimated AEE of walking (move II minus reference, 0.21 kcal/min), walking up-/downhill (0.06 kcal/min) and stair walking (upstairs: 0.13 kcal/min; downstairs: 0.29 kcal/min) and underestimated AEE of walking fast (-0.11 kcal/min) and jogging (-0.93 kcal/min).
Conclusions: Our data suggest that the activity monitor using activity-dependent calculation models is more appropriate for predicting AEE in daily life than the activity monitor using a single regression model.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3938775 | PMC |
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0090606 | PLOS |
Int J Sports Med
January 2025
Shanghai National Clinical Research Center for Metabolic Diseases, Key Laboratory for Endocrine and Metabolic Diseases of the National Health Commission of the PR China, Shanghai National Center for Translational Medicine, Ruijin Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China.
This study examines the energy expenditure and physiological responses associated with short-term quadrupedal locomotion compared to bipedal walking in humans. It aims to support evolutionary theory and explore quadrupedal locomotion's potential for enhancing fitness and health. In a randomized crossover design, 12 participants performed quadrupedal and bipedal walking on a treadmill at identical speeds.
View Article and Find Full Text PDFOrthop Surg
December 2024
Department of Bone and Soft Tissue Oncology, Tianjin Hospital, Tianjin, China.
Objective: The gait analysis of patients after surgery for tumors around the knee joint relies on the use of a three-dimensional motion capture system. However, obtaining long-term, free-standing, real-world gait data with three-dimensional gait analysis is challenging. In this study, we utilized a portable gait analyzer to collect gait data from patients who underwent rotating hinge knee megaprosthesis (RHK) and total knee arthroplasty (TKA), this study aims to compare via gait analysis patients who underwent megaprosthesis with patients with TKA.
View Article and Find Full Text PDFPLoS One
August 2024
Department of Applied Health Sciences, Division of Physiotherapy, Hochschule für Gesundheit, University of Applied Sciences, Bochum, Germany.
Sports (Basel)
March 2024
Department of Physical Therapy, College of Allied Health Sciences, East Carolina University, Greenville, NC 27834, USA.
A goal of mobile monitoring is to approximate metabolic energy expenditure (EE) during activities of daily living and exercise. Many physical activity monitors are inaccurate with respect to estimated EE and differentiating between activities that occur over short intervals. The objective of our study was to assess the validity of the SenseWear Armband (SWA) compared to indirect calorimetry (IC) during short intervals of walking and running.
View Article and Find Full Text PDFEur J Appl Physiol
April 2024
Institute for Sport and Physical Activity Research, School of Sport Science and Physical Activity, University of Bedfordshire, Bedford, UK.
Purpose: This study examined the acute effects of interrupting sitting with light-intensity walking on postprandial cardiometabolic risk markers in South Asian adults.
Methods: South Asians with overweight/obesity (n = 19; body mass index [BMI] > 23 kg·m) and normal-weight (n = 8; BMI 18.0-22.