Multi-dye residue analysis of triarylmethane, xanthene, phenothiazine and phenoxazine dyes in fish tissues by ultra-performance liquid chromatography-tandem mass spectrometry.

J Chromatogr B Analyt Technol Biomed Life Sci

Scientific Institute of Public Health, Food, Medicines and Consumer Safety, Chemical Residues and Contaminants, Juliette Wytsmanstraat 14, 1050 Brussel, Belgium.

Published: March 2014

Beside the possible illegal use of malachite green in aquaculture, other familiar dyes could also been applied by fraudulent producers due to their antiseptic and antibacterial activity. In this contribution, a new sensitive multi-residue method was developed to determine triarylmethane, xanthene, phenothiazine and phenoxazine dyes in fish by ultra-performance liquid chromatography-tandem mass spectrometry. Samples were extracted with acetonitrile, followed by an oxidation step using 2,3-dichloro-5,6-dicyanobenzoquinone. Further clean-up was performed by tandem solid phase extraction using weak and strong cation exchange cartridges. Extracts were analysed by UPLC-MS(n) operating in the positive electrospray ionisation mode (ESI+). The fourteen dyes were separated within only 12min on a C18 BEH column using 1mM ammonium acetate in water at pH 4.5 and acetonitrile as mobile phases at a flowrate of 0.4mLmin(-1). The presented method was validated as defined by the European Union and scientific literature. Good linearity (R ≥0.99 and goodness-of-fit (g) ≤10%) was achieved over the tested concentration range (0.25-2ngg(-1)). Limit of quantification was 0.25ngg(-1) for all dyes, with a signal-to-noise ratio of at least 10/1. This is at least 5 to 10 times lower than previous published methods. Limits of detection were all <0.1ngg(-1). Precision and trueness fell within the criteria requested by the EC requirements for this concentration range. Decision limit (CCα) and detection capability (CCβ) were all <1 and <0.25ngg(-1), respectively. Due to background levels of the xanthene dyes, the two rhodamine dyes could only be determined above 0.75ngg(-1). For these dyes, the method can only be used for screening purposes. To show the applicability of the method, a monitoring study was performed to investigate the occurrence of artificial dyes in wildlife European eel in Flemish rivers.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jchromb.2014.02.002DOI Listing

Publication Analysis

Top Keywords

triarylmethane xanthene
8
xanthene phenothiazine
8
phenothiazine phenoxazine
8
phenoxazine dyes
8
dyes fish
8
ultra-performance liquid
8
liquid chromatography-tandem
8
chromatography-tandem mass
8
mass spectrometry
8
dyes
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!